MT9V022IA7ATM Aptina LLC, MT9V022IA7ATM Datasheet - Page 24

SENSOR IMAGE VGA MONO 52IBGA

MT9V022IA7ATM

Manufacturer Part Number
MT9V022IA7ATM
Description
SENSOR IMAGE VGA MONO 52IBGA
Manufacturer
Aptina LLC
Type
CMOS Imagingr
Series
DigitalClarity®r
Datasheets

Specifications of MT9V022IA7ATM

Pixel Size
6µm x 6µm
Active Pixel Array
752H x 480V
Frames Per Second
60
Voltage - Supply
3.3V
Package / Case
52-IBGA
Sensor Image Color Type
Monochrome
Sensor Image Size Range
250,920 to 480,000Pixels
Sensor Image Size
752x480Pixels
Operating Supply Voltage (min)
3V
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (max)
3.6V
Operating Temp Range
-40C to 85C
Package Type
IBGA
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
52
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
557-1205

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MT9V022IA7ATM-DP
0
Company:
Part Number:
MT9V022IA7ATM-DP
Quantity:
4 500
Window Control
Blanking Control
Pixel Integration Control
Total Integration
R0x0B Total Shutter Width (In Terms of Number of Rows)
PDF: 3295348826/Source:7478516499
MT9V022_DS - Rev.H 6/10 EN
Registers R0x01 column start, R0x02 Row Start, R0x03 window height (row size), and
R0x04 Window Width (column size) control the size and starting coordinates of the
window.
The values programmed in the window height and width registers are the exact window
height and width out of the sensor. The window start value should never be set below
four.
To read out the dark rows set bit 6 of R0x0D. In addition, bit 7 of R0x0D can be used to
display the dark columns in the image.
Horizontal blanking and vertical blanking registers R0x05 and R0x06 respectively control
the blanking time in a row (horizontal blanking) and between frames (vertical blanking).
• Horizontal blanking is specified in terms of pixel clocks.
• Vertical blanking is specified in terms of numbers of rows.
The actual imager timing can be calculated using Table 4 on page 13 and Table 5 on
page 14 which describe “Row Timing and FRAME_VALID/LINE_VALID signals.” The
minimum number of vertical blank rows is 4.
This register (along with the window width and horizontal blanking registers) controls
the integration time for the pixels.
The actual total integration time,
Typically, the value of R0x0B (total shutter width) is limited to the number of rows per
frame (which includes vertical blanking rows), such that the frame rate is not affected by
the integration time. If R0x0B is increased beyond the total number of rows per frame, it
is required to add additional blanking rows using R0x06 as needed. A second constraint
is that
60Hz flicker, this means frame time must be a multiple of 1/120 of a second. Under 50Hz
flicker, frame time must be a multiple of 1/100 of a second.
t
The number of rows integration is equal to the result of automatic exposure control
(AEC) which may vary from frame to frame, or, if AEC is disabled, the value in R0x0B
Row time = (R0x04 + R0x05) master clock periods
Overhead = (R0x04 + R0x05 – 255) master clock periods
INT = (Number of rows of integration × row time) + Overhead, where:
t
INT must be adjusted to avoid banding in the image from light flicker. Under
24
t
INT, is:
MT9V022: 1/3-Inch Wide-VGA Digital Image Sensor
Aptina reserves the right to change products or specifications without notice.
©2005 Aptina Imaging Corporation. All rights reserved.
Feature Description