DRT2-MD32B Omron, DRT2-MD32B Datasheet - Page 325

no-image

DRT2-MD32B

Manufacturer Part Number
DRT2-MD32B
Description
16In,16Out Horiz MIL Conn NPN
Manufacturer
Omron
Datasheet

Specifications of DRT2-MD32B

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Overview of Analog Slaves
7-1-8
304
Allocating
analog
input only in
the Master
Allocating
other values
(not analog
input) in the
Master
Allocating the alarm output for
analog input, peak/bottom,
top/valley, or rate of change
value in the Master
Monitoring the cumulated value
from the Configurator.
Application
Procedure for Allocating I/O in the Master
Using default allo-
cation
Scaling with
desired industry
unit
Averaging exter-
nal analog inputs
Allocating the
maximum (peak)
or minimum (bot-
tom) value in the
Master
Allocating the top
or valley value in
the Master
Allocating top or
valley timing in the
Master
Allocating the rate
of change in the
Master
Not required.
Set the scaling func-
tion.
Set the moving average
processing operation.
Set the peak/bottom
hold function.
Set the top/valley hold
function.
Set the top/valley hold
function.
Set the rate of change
operation function.
Set the HH, H, L, and
LL alarms for the com-
parator function.
Set the cumulative
count function.
Slave’s Edit Device Parameters Window
Set using the Configurator in the
Enable/disable
functions
Step 1
Not required.
Not required.
Not required.
Allocate the
maximum (peak)
or minimum (bot-
tom) value as
Analog Data 1,
Analog Data 2,
Temperature
Data 1, or Tem-
perature Data 2.
Allocate the top
or valley value as
Analog Data 1,
Analog Data 2,
Temperature
Data 1, or Tem-
perature Data 2.
Not required.
Allocate the rate
of change value
in Analog Data 1,
Analog Data 2,
Temperature
Data 1, or Tem-
perature Data 2.
Allocate any of
the analog data
types in Analog
Data 1 or Tem-
perature Data 1.
Not required.
Select analog
Step 2
data
in the Slave’s Edit
Not required.
Not required.
Not required.
Select an I/O data
(pattern) that
includes either
Analog Data 1,
Analog Data 2,
Temperature Data
1, or Temperature
Data 2, and select
the Hold Flag.
Select an I/O data
(pattern) that
includes Analog
Data 1, Analog
Data 2, Tempera-
ture Data 1, or
Temperature Data
2, and select the
Hold Flag.
Select an I/O data
(pattern) that
includes the
Top/Valley Detec-
tion Timing Flag,
and select the
Hold Flag.
Select an I/O data
(pattern) that
includes Analog
Data 1, Analog
Data 2, Tempera-
ture Data 1, or
Temperature Data
2.
Select an I/O data
(pattern) that
includes the Ana-
log Status Flags.
Not required.
Connection Path
1. Allocate I/O
combinations
under Default
Set using the
Configurator
data in fixed
Parameters
Window
Device
Step 3
---
---
---
Specify either Ana-
log Data 1, Analog
Data 2, Tempera-
ture Data 1, or
Temperature Data
2, and the Hold
Flag.
Specify either Ana-
log Data 1, Analog
Data 2, Tempera-
ture Data 1, or
Temperature Data
2, and the Hold
Flag.
Specify the
Top/Valley Detec-
tion Timing Flag
and the Hold Flag.
Specify either Ana-
log Data 1, Analog
Data 2, Tempera-
ture Data 1, or
Temperature Data
2.
Specify the Ana-
log Status Flags.
Not required.
user-defined data
Connection Tab
in user-defined
in the Master’s
Set using the
Configurator
Edit Device
2. Allocate
Section 7-1
Parameter
under the
Window
area

Related parts for DRT2-MD32B