XC3S500E-4FT256I Xilinx Inc, XC3S500E-4FT256I Datasheet - Page 138

no-image

XC3S500E-4FT256I

Manufacturer Part Number
XC3S500E-4FT256I
Description
FPGA Spartan®-3E Family 500K Gates 10476 Cells 572MHz 90nm (CMOS) Technology 1.2V 256-Pin FTBGA
Manufacturer
Xilinx Inc
Series
Spartan™-3Er
Datasheet

Specifications of XC3S500E-4FT256I

Package
256FTBGA
Family Name
Spartan®-3E
Device Logic Cells
10476
Device Logic Units
1164
Device System Gates
500000
Number Of Registers
9312
Maximum Internal Frequency
572 MHz
Typical Operating Supply Voltage
1.2 V
Maximum Number Of User I/os
190
Ram Bits
368640
Number Of Logic Elements/cells
10476
Number Of Labs/clbs
1164
Total Ram Bits
368640
Number Of I /o
190
Number Of Gates
500000
Voltage - Supply
1.14 V ~ 1.26 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
256-LBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XC3S500E-4FT256I
Manufacturer:
XILINX
Quantity:
1 400
Part Number:
XC3S500E-4FT256I
Manufacturer:
XILINX
Quantity:
360
Part Number:
XC3S500E-4FT256I
Manufacturer:
Xilinx Inc
Quantity:
10 000
Part Number:
XC3S500E-4FT256I
Manufacturer:
XILINX
0
Part Number:
XC3S500E-4FT256I
Manufacturer:
XILXIN
Quantity:
20 000
Company:
Part Number:
XC3S500E-4FT256I
Quantity:
38
DC and Switching Characteristics
Configurable Logic Block (CLB) Timing
Table 98: CLB (SLICEM) Timing
138
Notes:
1.
Clock-to-Output Times
T
Setup Times
T
T
Hold Times
T
T
Clock Timing
T
T
F
Propagation Times
T
Set/Reset Pulse Width
T
AS
AH
CKO
DICK
CKDI
CH
CL
TOG
ILO
RPW_CLB
The numbers in this table are based on the operating conditions set forth in
Symbol
When reading from the FFX (FFY) Flip-Flop,
the time from the active transition at the CLK
input to data appearing at the XQ (YQ) output
Time from the setup of data at the F or G input
to the active transition at the CLK input of the
CLB
Time from the setup of data at the BX or BY
input to the active transition at the CLK input of
the CLB
Time from the active transition at the CLK input
to the point where data is last held at the F or
G input
Time from the active transition at the CLK input
to the point where data is last held at the BX or
BY input
The High pulse width of the CLB’s CLK signal
The Low pulse width of the CLK signal
Toggle frequency (for export control)
The time it takes for data to travel from the
CLB’s F (G) input to the X (Y) output
The minimum allowable pulse width, High or
Low, to the CLB’s SR input
Description
www.xilinx.com
Table
0.46
1.58
0.70
0.70
1.57
Min
0
0
0
-
-
77.
-5
Max
0.52
0.66
657
Speed Grade
-
-
-
-
-
-
-
0.52
1.81
0.80
0.80
1.80
Min
DS312-3 (v3.8) August 26, 2009
0
0
0
-
-
-4
Product Specification
Max
0.60
0.76
572
-
-
-
-
-
-
-
Units
MHz
ns
ns
ns
ns
ns
ns
ns
ns
ns
R

Related parts for XC3S500E-4FT256I