SAA7324H NXP Semiconductors, SAA7324H Datasheet - Page 34

SAA7324H

Manufacturer Part Number
SAA7324H
Description
Manufacturer
NXP Semiconductors
Datasheet

Specifications of SAA7324H

Operating Temperature (max)
70C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
64
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SAA7324H
Manufacturer:
PHILIPS
Quantity:
84
Part Number:
SAA7324H/M2B,557
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
SAA7324H/T/M2B
Manufacturer:
NXP
Quantity:
5 000
Part Number:
SAA7324H/T/M2B
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Philips Semiconductors
It should be noted that RAB must be held LOW; the
command or data is interpreted by the SAA7324 after the
HIGH-to-LOW transition of SILD; there must be a
minimum time of 70 s between SILD pulses.
7.15.1.7
The same data byte can be repeated by applying extra
SILD pulses as illustrated in Fig.30. SCL must be HIGH
between the SILD pulses.
7.15.1.8
A read data command is used to transfer data (status
information) to the microcontroller, using the protocol
shown in Fig.31. The first byte written determines the type
of command. After this byte a variable number of bytes can
be read. It should be noted that RAB must be held LOW;
after the end of the command byte (LOW-to-HIGH
transition on SILD) there must be a delay of 70 s before
reading data is started (i.e. the next HIGH-to-LOW
transition on SILD); there must be a minimum time of 70 s
between SILD pulses.
7.15.2
Bytes are transferred over the interface in groups (i.e.
servo commands) of which there are two types: write data
commands and read data commands.
The sequence for a write data command (that requires
3 data bytes) is as follows:
2000 Jun 26
Digital servo processor and Compact Disc
decoder with integrated DAC (CD10 II)
M
Writing repeated data in servo commands
Read servo commands
ICROCONTROLLER INTERFACE
(microcontroller)
(microcontroller)
(microcontroller)
(SAA7324)
SDA
SCL
SDA
RAB
Fig.23 Microcontroller write protocol for registers 0 to F.
A3
(I
2
C-
BUS MODE
A2
A1
)
high-impedance
A0
34
D3
1. Send START condition
2. Send address 30H (write)
3. Write command byte
4. Write data byte 1
5. Write data byte 2
6. Write data byte 3
7. Send STOP condition.
It should be noted that more than one command can be
sent in one write sequence.
The sequence for a read data command (that reads 2 data
bytes) is as follows:
1. Send START condition
2. Send address 30H (write)
3. Write command byte
4. Send STOP condition
5. Send START condition
6. Send address 31H (read)
7. Read data byte 1
8. Read data byte 2
9. Send STOP condition.
It should be noted that the timing constraints specified for
the read and write servo commands must still be adhered
to.
D2
D1
D0
Product specification
MGS181
SAA7324

Related parts for SAA7324H