MC68MH360EM33L Freescale Semiconductor, MC68MH360EM33L Datasheet - Page 219

no-image

MC68MH360EM33L

Manufacturer Part Number
MC68MH360EM33L
Description
IC MPU QUICC ETHER 33MHZ 240FQFP
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MC68MH360EM33L

Processor Type
M683xx 32-Bit
Speed
33MHz
Voltage
5V
Mounting Type
Surface Mount
Package / Case
240-FQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Features
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC68MH360EM33L
Manufacturer:
MOTOLOLA
Quantity:
319
Part Number:
MC68MH360EM33L
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Operand Data:
Result Data:
5.6.2.8.12 Resume Execution (GO). The pipeline is flushed and refilled before normal
instruction execution is resumed. Prefetching begins at the return PC and current privilege
level. If either the PC or SR is altered during BDM, the updated value of these registers is
used when prefetching commences.
Command Format:
Command Sequence:
Operand Data:
Result Data:
5.6.2.8.13 Call User Code (CALL). This instruction provides a convenient way to patch
user code. The return PC is stacked at the location pointed to by the current SP. The stacked
PC serves as a return address to be restored by the RTS command that terminates the
patch routine. After stacking is complete, the 32-bit operand data is loaded into the PC. The
pipeline is flushed and refilled from the location pointed to by the new PC, BDM is exited,
and normal mode instruction execution begins.
MOTOROLA
A single operand is data to be written to the memory location. Byte data is transmitted as
a 16-bit word, justified in the least significant byte; 16- and 32-bit operands are transmitted
as 16 and 32 bits, respectively.
Status is returned as in the WRITE command: $0FFFF for a successful operation and
$10001 for a bus or address error during write.
15
None
None
0
14
0
The processor exits BDM when a bus error or address error oc-
curs on the first instruction prefetch from the new PC—the error
is trapped as a normal mode exception. The stacked value of the
current PC may not be valid in this case, depending on the state
of the machine prior to entering BDM. For address error, the PC
does not reflect the true return PC. Instead, the stacked fault ad-
dress is the (odd) return PC.
13
0
12
0
Freescale Semiconductor, Inc.
11
1
For More Information On This Product,
GO
???
10
1
MC68360 USER’S MANUAL
Go to: www.freescale.com
9
0
NOTE
8
0
NORMAL
"ILLEGAL"
MODE
XXX
7
0
6
0
"NOT READY"
NEXT CMD
5
0
4
0
0
3
2
0
1
0
CPU32+
5-77
0
0

Related parts for MC68MH360EM33L