3–4
Stratix II Development Board
1
Factory & User Configurations
The configuration controller can manage four separate Stratix II device
configurations as HEXOUT data stored in flash memory: three user
designs and a factory design. On power-up, the configuration controller
reads one of the four (user or factory) designs from the flash memory and
programs the Stratix II device accordingly. The user can select which
design the Stratix II device is programmed with by setting the DIP
switches on SW2.
DIP switches 1 through 3 on SW2 select one of four possible Stratix II
configuration images upon power-up. When DIP switch 4 is in the
“OPEN” position the configuration controller is enabled. If DIP switch 4
is in the “OPEN” position and there are no valid user-defined images, the
Stratix II device is programmed with the factory configuration.
shows the DIP switch combinations used to select the available images.
See
1
An alternative method of configuring the device with the factory design
is to press push-button switch SW3.
1
User0
User1
User2
Factory
Table 1. Configuration DIP Switch (SW2) Combinations
“Non-Volatile Configuration” on page 3–2
Image
Intel-format HEXOUT files contain data that is not actually
written to the flash memory. The Write2Flash executable file
(provided in the <installation directory>/utilities/
Flash_Programmer directory) parses the HEXOUT file and
creates a file with the extension .hexout.flash that contains the
data to be written to flash memory. The designer can then send
this file serially to the board via an RS-232 cable and write it to
flash memory by the factory configuration as described in the
next section.
On the Stratix II EP2S180 DSP board, only the factory image and
User0 are available because of the size of the configuration files
for the EP2S180 device.
Switch 4 must be set to “OPEN” to enable the configuration
controller.
Reference Manual
Switch 1
Closed
Closed
Open
Open
Switch 2
Closed
Closed
Open
Open
for more details.
Switch 3
Closed
Closed
Closed
Open
Altera Corporation
August 2006
Switch 4
Open
Open
Open
Open
Table 1