AT32UC3A0256 Atmel Corporation, AT32UC3A0256 Datasheet - Page 704

no-image

AT32UC3A0256

Manufacturer Part Number
AT32UC3A0256
Description
Manufacturer
Atmel Corporation

Specifications of AT32UC3A0256

Flash (kbytes)
256 Kbytes
Pin Count
144
Max. Operating Frequency
66 MHz
Cpu
32-bit AVR
# Of Touch Channels
32
Hardware Qtouch Acquisition
No
Max I/o Pins
109
Ext Interrupts
109
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device + OTG
Spi
6
Twi (i2c)
1
Uart
4
Ssc
1
Ethernet
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Dac Channels
2
Dac Resolution (bits)
16
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
64
Self Program Memory
YES
External Bus Interface
1
Dram Memory
sdram
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.0-3.6 or (1.65-1.95+3.0-3.6)
Operating Voltage (vcc)
3.0-3.6 or (1.65-1.95+3.0-3.6)
Fpu
No
Mpu / Mmu
Yes / No
Timers
10
Output Compare Channels
16
Input Capture Channels
6
Pwm Channels
13
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
AT32UC3A0256
Quantity:
2 000
Part Number:
AT32UC3A0256-ALUR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3A0256-ALUT
Manufacturer:
ATMEL
Quantity:
167
Part Number:
AT32UC3A0256-ALUT
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3A0256-CTUR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3A0256-CTUT
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3A0256AU-ALUT
Manufacturer:
Atmel
Quantity:
10 000
32058K AVR32-01/12
Figure 33-3. GOVRE and OVREx Flag Behavior
OVRE0(SR)
GOVRE(SR)
CH0(CHSR)
DRDY(ASR)
CH1(CHSR)
TRIGGER
EOC0(SR)
EOC1(SR)
LCDR
CRD0
CRD1
Undefined Data
Undefined Data
If the CDR is not read before further incoming data is converted, the corresponding Overrun
Error (OVRE) flag is set in the Status Register (SR).
In the same way, new data converted when DRDY is high sets the bit GOVRE (General Overrun
Error) in SR.
The OVRE and GOVRE flags are automatically cleared when SR is read.
Warning: If the corresponding channel is disabled during a conversion or if it is disabled and
then reenabled during a conversion, its associated data and its corresponding EOC and OVRE
flags in SR are unpredictable.
Conversion
Undefined Data
Conversion
Data A
Data A
Data B
Conversion
Data B
Data C
AT32UC3A
Data C
Read CDR1
Read CDR0
Read SR
704