SAM7X512 Atmel Corporation, SAM7X512 Datasheet - Page 295

no-image

SAM7X512

Manufacturer Part Number
SAM7X512
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM7X512

Flash (kbytes)
512 Kbytes
Pin Count
100
Max. Operating Frequency
55 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
62
Ext Interrupts
62
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
2
Twi (i2c)
1
Uart
3
Can
1
Ssc
1
Ethernet
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
128
Self Program Memory
NO
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.3
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
29.6.1
Register Name:
Access Type:
• START: Send a START Condition
0 = No effect.
1 = A frame beginning with a START bit is transmitted according to the features defined in the mode register.
This action is necessary when the TWI peripheral wants to read data from a slave. When configured in Master Mode with a
write operation, a frame is sent as soon as the user writes a character in the Transmit Holding Register (TWI_THR).
• STOP: Send a STOP Condition
0 = No effect.
1 = STOP Condition is sent just after completing the current byte transmission in master read mode.
• MSEN: TWI Master Transfer Enabled
0 = No effect.
1 = If MSDIS = 0, the master data transfer is enabled.
• MSDIS: TWI Master Transfer Disabled
0 = No effect.
1 = The master data transfer is disabled, all pending data is transmitted. The shifter and holding characters (if they contain
data) are transmitted in case of write operation. In read operation, the character being transferred must be completely
received before disabling.
• SWRST: Software Reset
0 = No effect.
1 = Equivalent to a system reset.
6120I–ATARM–06-Apr-11
SWRST
– In single data byte master read, the START and STOP must both be set.
– In multiple data bytes master read, the STOP must be set after the last data received but one.
– In master read mode, if a NACK bit is received, the STOP is automatically performed.
– In multiple data write operation, when both THR and shift register are empty, a STOP condition is automatically
31
23
15
7
sent.
TWI Control Register
30
22
14
TWI_CR
Write-only
6
29
21
13
5
28
20
12
4
MSDIS
27
19
11
3
MSEN
26
18
10
2
SAM7X512/256/128
STOP
25
17
9
1
START
24
16
8
0
295

Related parts for SAM7X512