SAM7X512 Atmel Corporation, SAM7X512 Datasheet - Page 541

no-image

SAM7X512

Manufacturer Part Number
SAM7X512
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM7X512

Flash (kbytes)
512 Kbytes
Pin Count
100
Max. Operating Frequency
55 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
62
Ext Interrupts
62
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
2
Twi (i2c)
1
Uart
3
Can
1
Ssc
1
Ethernet
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
128
Self Program Memory
NO
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.3
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
SAM7X512/256/128
• BOFF: Bus Off Mode
0 = CAN controller is not in Bus Off Mode.
1 = CAN controller is in Bus Off Mode.
This flag is set depending on TEC counter value. A node is bus off when TEC counter is greater or equal to 256 (decimal).
This flag is automatically reset when above condition is not satisfied. Refer to
Section 36.6.4.6 “Error Interrupt Handler” on
page 515
for more information.
• SLEEP: CAN controller in Low power Mode
0 = CAN controller is not in low power mode.
1 = CAN controller is in low power mode.
This flag is automatically reset when Low power mode is disabled
• WAKEUP: CAN controller is not in Low power Mode
0 = CAN controller is in low power mode.
1 = CAN controller is not in low power mode.
When a WAKEUP event occurs, the CAN controller is synchronized with the bus activity. Messages can be transmitted or
received. The CAN controller clock must be available when a WAKEUP event occurs. This flag is automatically reset when
the CAN Controller enters Low Power mode.
• TOVF: Timer Overflow
0 = The timer has not rolled-over FFFFh to 0000h.
1 = The timer rolls-over FFFFh to 0000h.
This flag is automatically cleared by reading CAN_SR register.
• TSTP Timestamp
0 = No bus activity has been detected.
1 = A start of frame or an end of frame has been detected (according to the TEOF field in the CAN_MR register).
This flag is automatically cleared by reading the CAN_SR register.
• CERR: Mailbox CRC Error
0 = No CRC error occurred during a previous transfer.
1 = A CRC error occurred during a previous transfer.
A CRC error has been detected during last reception.
This flag is automatically cleared by reading CAN_SR register.
• SERR: Mailbox Stuffing Error
0 = No stuffing error occurred during a previous transfer.
1 = A stuffing error occurred during a previous transfer.
A form error results from the detection of more than five consecutive bit with the same polarity.
This flag is automatically cleared by reading CAN_SR register.
541
6120I–ATARM–06-Apr-11

Related parts for SAM7X512