S1D10605 Epson Electronics America, Inc., S1D10605 Datasheet - Page 582

no-image

S1D10605

Manufacturer Part Number
S1D10605
Description
S1d15000 Series Lcd Driver With Ram
Manufacturer
Epson Electronics America, Inc.
Datasheet
(11) Read modify write
This command is used paired with End command. Once this command is issued, the column address is not incremented
by Display data read command, but is incremented by Display data write command. This mode is maintained until End
command is issued. When End command is issued, the column address returns to the address it was at when Read modify
write command was issued. This function makes it possible to reduce the MPU load when there are the data to change
repeatedly in a specified display region, such as blinking cursor.
Rev. 1.1a
*When End command is issued, only column address returns to the address it was at when Read modify write
*Even if Read modify write mode, other commands besides Display data read/write can also be used. However,
command was issued, but page address does not return. Consequently, Read modify Write mode cannot be used
over pages.
Column address set command cannot be used.
A0
0
RD WR
E
1
R/W
0
D7
1
D6
1
D5
1
The sequence for cursor display
No
D4
0
Column Address Set
Read Modify Write
Page Address Set
D3
Dummy Read
Figure 19
Completed?
EPSON
0
Data Read
Data Write
End
D2
0
Yes
D1
0
D0
0
S1D15B01 Series
13–27

Related parts for S1D10605