XC3S100E Xilinx Corp., XC3S100E Datasheet - Page 141

no-image

XC3S100E

Manufacturer Part Number
XC3S100E
Description
Spartan-3e Fpga Family Complete Data Sheet
Manufacturer
Xilinx Corp.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XC3S100E
Manufacturer:
XILINX
0
Part Number:
XC3S100E-4CP132C
Manufacturer:
XILINX
0
Part Number:
XC3S100E-4CP132I
Manufacturer:
XILINX
0
Part Number:
XC3S100E-4CPG132C
Manufacturer:
Xilinx Inc
Quantity:
10 000
Part Number:
XC3S100E-4CPG132C
Manufacturer:
XILINX
0
Part Number:
XC3S100E-4CPG132C
Manufacturer:
XILINX/赛灵思
Quantity:
20 000
Part Number:
XC3S100E-4CPG132C
0
Part Number:
XC3S100E-4TQ144C
Manufacturer:
XILINX
Quantity:
57
Part Number:
XC3S100E-4TQ144I
Manufacturer:
XILINX/赛灵思
Quantity:
20 000
Part Number:
XC3S100E-4TQG144C
Manufacturer:
XILINX
Quantity:
308
Table 98: CLB Distributed RAM Switching Characteristics
Table 99: CLB Shift Register Switching Characteristics
DS312-3 (v3.6) May 29, 2007
Product Specification
Clock-to-Output Times
Setup Times
Hold Times
Clock Pulse Width
Clock-to-Output Times
Setup Times
Hold Times
Clock Pulse Width
T
T
WPH
WPH
T
Symbol
Symbol
T
T
T
AH,
T
SHCKO
SRLDS
SRLDH
T
T
T
T
REG
WS
DH
DS
AS
, T
, T
T
WH
WPL
WPL
R
Time from the active edge at the CLK input to data
appearing on the distributed RAM output
Setup time of data at the BX or BY input before the active
transition at the CLK input of the distributed RAM
Setup time of the F/G address inputs before the active
transition at the CLK input of the distributed RAM
Setup time of the write enable input before the active
transition at the CLK input of the distributed RAM
Hold time of the BX, BY data inputs after the active
transition at the CLK input of the distributed RAM
Hold time of the F/G address inputs or the write enable
input after the active transition at the CLK input of the
distributed RAM
Minimum High or Low pulse width at CLK input
Time from the active edge at the CLK input to data
appearing on the shift register output
Setup time of data at the BX or BY input before the active
transition at the CLK input of the shift register
Hold time of the BX or BY data input after the active
transition at the CLK input of the shift register
Minimum High or Low pulse width at CLK input
Description
Description
www.xilinx.com
0.40
0.46
0.34
0.13
0.88
0.41
0.14
0.88
Min
Min
0
-
-
-5
-5
DC and Switching Characteristics
Max
2.05
Max
3.62
-
-
-
-
-
-
-
-
-
0.46
0.52
0.40
0.15
1.01
0.46
0.16
1.01
Min
Min
0
-
-
-4
-4
Max
2.35
Max
4.16
-
-
-
-
-
-
-
-
-
Units
Units
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
141