DS26502 Maxim Integrated Products, DS26502 Datasheet - Page 55

no-image

DS26502

Manufacturer Part Number
DS26502
Description
T1/E1/J1/64KCC BITS Element
Manufacturer
Maxim Integrated Products
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS26502
Manufacturer:
ELPIDA
Quantity:
12 388
Part Number:
DS26502L+
Manufacturer:
Maxim Integrated Products
Quantity:
135
Part Number:
DS26502L+
Manufacturer:
MAXIM
Quantity:
3
Part Number:
DS26502L+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Company:
Part Number:
DS26502L+
Quantity:
1 680
Part Number:
DS26502LB1
Manufacturer:
ST
0
Part Number:
DS26502LN+
Manufacturer:
Maxim Integrated Products
Quantity:
135
Part Number:
DS26502LN+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS26502LN+
Manufacturer:
DALLAS
Quantity:
20 000
DS26502 T1/E1/J1/64KCC BITS Element
11.3 Receive BOC
The receive BOC function is enabled by setting BOCC.4 = 1. The RFDL register will now operate as the
receive BOC message and information register. The lower six bits of the RFDL register (BOC message
bits) are preset to all ones. When the BOC bits change state, the BOC change of state indicator, SR3.0
will alert the host. The host will then read the RFDL register to get the BOC message. A change of state
will occur when either a new BOC code has been present for time determined by the receive BOC filter
bits, RBF0 and RBF1, in the BOCC register.
To receive a BOC, use the following:
1) Set integration time via BOCC.1 and BOCC.2.
2) Enable the receive BOC function (BOCC.4 = 1).
3) Enable interrupt (IMR3.0 = 1).
4) Wait for interrupt to occur.
5) Read the RFDL register.
6) The lower six bits of the RFDL register is the message.
www.DataSheet4U.com
55 of 124