9.9.17 Framer Payload Loopbacks
The framer, payload, and remote loopbacks are controlled by RCR3.
Table 9-35. Register Related to Framer Payload Loopbacks
Framer Loopback
Payload Loopback
Remote Loopback
Note: The addresses shown above are for Framer 1. Addresses for Framers 2 to 8 can be calculated using the following: Framer n = (Framer 1
address + (n - 1) x 200hex), where n = 2 to 8 for Framers 2 to 8.
RECEIVE CONTROL
REGISTER 3 (RCR3)
ADDRESSES
FRAMER 1
083h
083h
083h
Transmit data output from the framer is looped back to the receiver.
Data recovered by the receiver is looped back to the transmitter.
The 192-bit payload data is looped back to the transmitter.