w83977atg Winbond Electronics Corp America, w83977atg Datasheet - Page 44

no-image

w83977atg

Manufacturer Part Number
w83977atg
Description
W83877tf Plus Kbc, Gp I/o, Wake-up, Fir, Cir, Pb-free
Manufacturer
Winbond Electronics Corp America
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
w83977atg-AW
Manufacturer:
Nuvoton Technology Corporation of America
Quantity:
10 000
DRATE1 DRATE0 (Bit 1, 0):
These two bits select the data rate of the FDC and reduced write current control.
00 500 KB/S (MFM), 250 KB/S (FM), RWC = 1
01 300 KB/S (MFM), 150 KB/S (FM), RWC = 0
10 250 KB/S (MFM), 125 KB/S (FM), RWC = 0
11 1 MB/S (MFM), Illegal (FM), RWC = 1
The 2 MB/S data rate for Tape drive is only supported by setting 01 to DRATE1 and DRATE0 bits, as
well as setting 10 to DRT1 and DRT0 bits, which are two of the Configure Register CRF4 or CRF5 bits
in logic device 0. Please refer to the function description of CRF4 or CRF5 and data rate table for
individual data rates setting.
5.2.7
The Data Register consists of four status registers in a stack, with only one register presented to the
data bus at a time. This register stores data, commands, and parameters and provides diskette-drive
status information. Data bytes are passed through the data register to program or obtain results after
a command. In W83977ATF/ATG, this register defaults to FIFO disabled mode after reset. The FIFO
can change its value and enable its operation through the CONFIGURE command.
Status Register 0 (ST0)
7-6
FIFO Register (R/W base address + 5)
5
4
3
2
1-0
US1, US0 Drive Select:
00 Drive A selected
01 Drive B selected
10 Drive C selected
11 Drive D selected
HD Head address:
1 Head selected
0 Head selected
NR Not Ready:
1 Drive is not ready
0 Drive is ready
EC Equipment Check:
1 When a fault signal is received from the FDD or the track
0 signal fails to occur after 77 step pulses
0 No error
SE Seek end:
1 seek end
0 seek error
IC Interrupt Code:
00 Normal termination of command
01 Abnormal termination of command
10 Invalid command issue
11 Abnormal termination because the ready signal from FDD changed state during command executio
- 36 -