w83977atg Winbond Electronics Corp America, w83977atg Datasheet - Page 96

no-image

w83977atg

Manufacturer Part Number
w83977atg
Description
W83877tf Plus Kbc, Gp I/o, Wake-up, Fir, Cir, Pb-free
Manufacturer
Winbond Electronics Corp America
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
w83977atg-AW
Manufacturer:
Nuvoton Technology Corporation of America
Quantity:
10 000
8.2.7
8.2.8
When the EPP mode is selected in the configuration register, the standard and bi-directional modes
are also available. The PDx bus is in the standard or bi-directional mode when no EPP read, write, or
address cycle is currently being executed. In this condition all output signals are set by the SPP
Control Port and the direction is controlled by DIR of the Control Port.
A watchdog timer is required to prevent system lockup. The timer indicates that more than 10 μS have
elapsed from the start of the EPP cycle to the time WAIT is deasserted. The current EPP cycle is
aborted when a time-out occurs. The time-out condition is indicated in Status bit 0.
8.2.8.1
The EPP operates on a two-phase cycle. First, the host selects the register within the device for
subsequent operations. Second, the host performs a series of read and/or write byte operations to the
selected register. Four operations are supported on the EPP: Address Write, Data Write, Address
Read, and Data Read. All operations on the EPP device are performed asynchronously.
8.2.8.2
The EPP read/write operation can be completed under the following conditions:
a. If the nWait is active low, when the read cycle (nWrite inactive high, nDStrb/nAStrb active low) or
write cycle (nWrite active low, nDStrb/nAStrb active low) starts, the read/write cycle proceeds normally
and will be completed when nWait goes inactive high.
b. If nWait is inactive high, the read/write cycle will not start. It must wait until nWait changes to active
low, at which time it will start as described above.
8.2.8.3
The EPP read/write cycle can start without checking whether nWait is active or inactive. Once the
read/write cycle starts, however, it will not terminate until nWait changes from active low to inactive
high.
nWrite
PD<0:7>
Intr
nWait
PE
Select
nDStrb
nError
nInits
nAStrb
EPP NAME
EPP Pin Descriptions
EPP Operation
EPP Operation
EPP Version 1.9 Operation
EPP Version 1.7 Operation
TYPE
I/O
O
O
O
O
I
I
I
I
I
Denotes an address or data read or write operation.
Bi-directional EPP address and data bus.
Used by peripheral device to interrupt the host.
Inactive to acknowledge that data transfer is completed. Active to indicate that the
device is ready for the next transfer.
Paper end; same as SPP mode.
Printer selected status; same as SPP mode.
This signal is active low. It denotes a data read or write operation.
Error; same as SPP mode.
This signal is active low. When it is active, the EPP device is reset to its initial
operating mode.
This signal is active low. It denotes an address read or write operation.
- 88 -
EPP DESCRIPTION
W83977ATF/W83977ATG

Related parts for w83977atg