Bit 6—Receive Data Register Full (RDRF)
Bit 6 indicates that received data is stored in RDR.
Bit 6
RDRF
0
1
Note: If an error is detected in the receive data, or if the RE bit in SCR3 has been cleared to 0,
Bit 5—Overrun Error (OER)
Bit 5 indicates that an overrun error has occurred during reception.
Bit 5
OER
0
1
Notes: 1. When bit RE in SCR3 is cleared to 0, bit OER is not affected and retains its previous
RDR and bit RDRF are not affected and retain their previous state.
Note that if data reception is completed while bit RDRF is still set to 1, an overrun error
(OER) will result and the receive data will be lost.
2. RDR retains the receive data it held before the overrun error occurred, and data
state.
received after the error is lost. Reception cannot be continued with bit OER set to 1,
and in synchronous mode, transmission cannot be continued either.
There is no receive data in RDR
Clearing conditions:
After reading RDRF = 1, cleared by writing 0 to RDRF
When RDR data is read by an instruction
There is receive data in RDR
Setting condition:
When reception ends normally and receive data is transferred from RSR to RDR
Description
Reception in progress or completed *
Clearing condition:
After reading OER = 1, cleared by writing 0 to OER
An overrun error has occurred during reception *
Setting condition:
When reception is completed with RDRF set to 1
Description
1
Section 10 Serial Communication Interface
Rev. 7.00 Mar 10, 2005 page 345 of 652
2
REJ09B0042-0700
(initial value)
(initial value)