peb3456e Infineon Technologies Corporation, peb3456e Datasheet - Page 267

no-image

peb3456e

Manufacturer Part Number
peb3456e
Description
Channelized T3 Termination, With Ds3 Framer, M13 Multiplexer, T1/e1 Framers And 256-channel Hdlc/ppp Controller
Manufacturer
Infineon Technologies Corporation
Datasheet
AISC
LPC
FPL
CBP
Data Sheet
AIS Code Type
This bit field sets the AIS code.
0
1
Loopback Code.
This bit field selects the C-bit which will be inverted when loopback
requests are transmitted.
00
01
10
Full Payload Mode
This bit enables the M23 multiplex operation or the full payload rate
format.
0
1
C-bit parity mode
This bit enables M13 asynchronous mode or C-bit parity mode.
0
1
Set AIS to ’1010... ’ between overhead bits, C-bits all ‘0’s, X-bits
all ‘1’s (standard)
Set AIS to unframed all ‘1’s (non-standard).
Invert 1
Invert 2
Invert 3
Enable M23 multiplex operation. Payload is formed by
interleaving 7 asynchronous DS2 tributaries
Enable full payload rate format. The payload is one single, high
speed data stream without stuffing.
M13 asynchronous mode
C-bit parity mode
st
nd
rd
C-bit.
C-bit.
C-bit.
267
Register Description
PEB 3456 E
05.2001

Related parts for peb3456e