pxf4336 Infineon Technologies Corporation, pxf4336 Datasheet - Page 76

no-image

pxf4336

Manufacturer Part Number
pxf4336
Description
Abm Premium Atm Buf Fer Manager
Manufacturer
Infineon Technologies Corporation
Datasheet
DH
An example for the hysteresis mechanism is shown in
When TH is exceeded, a connection specific discard flag is set which is cleared again
when the buffer fill falls below TL. This flag is used by the cell acceptance algorithm to
differentiate between accept state and discard state.
Figure 3-19 Buffer Threshold with Hysteresis
Hysteresis is not used with packet discard and CLP1 discard thresholds.
Hysteresis avoids oscillation effects when the buffer fill is just stable at a certain value
and this value just coincides with a certain threshold. A stable buffer fill occurs when
input and output flow of the buffer are equal. However, due to cell clumping effects the
fill value will vary with a cell jitter in the range 10..100 cells. The hysteresis threshold
difference should be larger than the jitter.
3.4.1.7
The following pseudo-code provides the cell acceptance algorithm of the ABM-P based
on the parameter set listed in
3.4.1.7.1 Discard Conditions
/***** Basic Max/EPD conditions **********************************/
Data Sheet
TL
i
i
=0 disables the feature.
=
T L i
T H i
TH
B uffe r_size
i
Cell Acceptance Algorithm
(
TH
i
»
[
DH
i
+
C ell a ccep tanc e rate is h ig he r than cell em ission ra te
1
]
“DH” on Page 253
)
Chapter
, with DH
T H i is re ach ed, c ells of tra ffic class i a re d isca rd ed
= > C e ll acce ptan ce rate is redu ced ,
3.4.1.3.
i
ranging from 1 to 7.
76
som e con nectio ns red uce ra te
= > buffe r fill falls
provides the programming details.
b uffer falls b elow T Li
ce lls of traffic class i a re acce pted
= > em ptyin g rate sinks,
b uffer falls b elow T H i
ce lls of traffic class i a re still dis carde d
Figure 3-19
s et d is card flag
Functional Description
cle ar disca rd flag
below.
tim e
PXF 4336 V1.1
2001-12-17
ABM-P

Related parts for pxf4336