KSZ8895MQ_12 MICREL [Micrel Semiconductor], KSZ8895MQ_12 Datasheet - Page 73

no-image

KSZ8895MQ_12

Manufacturer Part Number
KSZ8895MQ_12
Description
Integrated 5-Port 10/100 Managed Ethernet Switch with MII/RMII interface
Manufacturer
MICREL [Micrel Semiconductor]
Datasheet
Micrel, Inc.
Advanced Control Registers (Continued)
Note:
Write to Register 111 will actually trigger a command. Read or write access will be decided by bit 4 of Register 110.
March 2012
Address
1-0
Address
Register 111 (0x6F): Indirect Access Control 1
7-0
Address
Register 112 (0x70): Indirect Data Register 8
68-64
Register 113 (0x71): Indirect Data Register 7
63-56
Register 114 (0x72): Indirect Data Register 6
55-48
Register 115 (0x73): Indirect Data Register 5
47-40
Register 116 (0x74): Indirect Data Register 4
39-32
Register 117 (0x75): Indirect Data Register 3
31-24
Register 118 (0x76): Indirect Data Register 2
23-16
Register 119 (0x77): Indirect Data Register 1
15-8
Register 120 (0x78): Indirect Data Register 0
7-0
Indirect Data
Indirect Data
Indirect Data
Indirect Data
Indirect Data
Indirect Data
Indirect Data
Indirect Data
Indirect Data
Name
Indirect Address High
Name
Name
Indirect Address Low
Description
Bit 68-64 of indirect data.
Bit 63-56 of indirect data.
Bit 55-48 of indirect data.
Bit 47-40 of indirect data.
Bit 39-32 of indirect data.
Bit of 31-24 of indirect data
Bit 23-16 of indirect data.
Bit 15-8 of indirect data.
Bit 7-0 of indirect data.
Description
Bit 9-8 of indirect address.
Description
Bit 7-0 of indirect address.
73
Mode
Mode
Mode
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
KSZ8895MQ/RQ/FMQ
M9999-032612-1.5
00000000
00000000
00000000
00000000
00000000
00000000
00000000
00000000
00000000
Default
Default
Default
00000
00

Related parts for KSZ8895MQ_12