HD6417606 RENESAS [Renesas Technology Corp], HD6417606 Datasheet - Page 318

no-image

HD6417606

Manufacturer Part Number
HD6417606
Description
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet
Section 12 Serial Communication Interface with FIFO (SCIF)
In receiving, the SCIF operates as follows:
1. The SCIF synchronizes with serial clock input or output and initializes internally.
2. Receive data is shifted into SCRSR in order from the LSB to the MSB. After receiving the
3. After setting RDF to 1, if the receive-data-full interrupt enable bit (RIE) is set to 1 in SCSCR,
Figure 12.17 shows an example of SCIF receive operation.
Rev. 4.00 Sep. 13, 2007 Page 292 of 502
REJ09B0239-0400
data, the SCIF checks the receive data can be loaded from SCRSR into SCFRDR or not. If this
check is passed, the SCIF stores the received data in SCFRDR. If the check is not passed
(overrun error is detected), further reception is prevented.
the SCIF requests a receive-data-full interrupt (RXI). If the ORER bit is set to 1 and the RIE
bit or REIE bit in SCSCR is also set to 1, the SCIF requests a break interrupt (BRI).
Synchronization
Serial data
ORER
clock
RDF
Figure 12.17 Example of SCIF Receive Operation
interrupt
request
RXI
Bit 7
RDF flag cleared
interrupt handler
Data read from
Bit 0
LSB
SCFRDR and
to 0 by RXI
One frame
interrupt
request
MSB
Bit 7
RXI
Bit 0
Bit 1
BRI interrupt request
Bit 6
by overrun error
Bit 7

Related parts for HD6417606