IS42S16100-10TI ISSI [Integrated Silicon Solution, Inc], IS42S16100-10TI Datasheet - Page 6

no-image

IS42S16100-10TI

Manufacturer Part Number
IS42S16100-10TI
Description
512K Words x 16 Bits x 2 Banks (16-MBIT) SYNCHRONOUS DYNAMIC RAM
Manufacturer
ISSI [Integrated Silicon Solution, Inc]
Datasheet
6
IS42S16100
AC CHARACTERISTICS
Symbol Parameter
Notes:
1. When power is first applied, memory operation should be started 100 µs after Vcc and VccQ reach their stipulated voltages. Also note that the
power-on sequence must be executed before starting memory operation.
2. Measured with t
3. The reference level is 1.4 V when measuring input signal timing. Rise and fall times are measured between V
4. Access time is measured at 1.4V with the load shown in the figure below.
5. The time t
output is in the high impedance state.
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
CHI
CL
OH
OH
LZ
HZ
HZ
DS
DH
AH
CKH
CS
CH
RC
RP
RCD
RRD
T
REF
CK
CK
AC
AC
AS
CKS
CKA
RAS
DPL
DPL
DAL
DAL
3
2
3
2
3
2
3
2
3
2
3
2
Clock Cycle Time
Access Time From CLK
CLK HIGH Level Width
CLK LOW Level Width
Output Data Hold Time
Output LOW Impedance Time
Output HIGH Impedance Time
Input Data Setup Time
Input Data Hold Time
Address Setup Time
Address Hold Time
CKE Setup Time
CKE Hold Time
CKE to CLK Recovery Delay Time
Command Setup Time (CS, RAS, CAS, WE, DQM)
Command Hold Time (CS, RAS, CAS, WE, DQM)
Command Period (REF to REF / ACT to ACT)
Command Period (ACT to PRE)
Command Period (PRE to ACT)
Active Command To Read / Write Command Delay Time
Command Period (ACT [0] to ACT[1])
Input Data To Precharge
Command Delay time
Input Data To Active / Refresh
Command Delay time (During Auto-Precharge)
Transition Time
Refresh Cycle Time (4096)
HZ
(max.) is defined as the time required for the output voltage to transition by ± 200 mV from V
T
= 1 ns.
(4)
(1,2,3)
(5)
Integrated Silicon Solution, Inc. — www.issi.com —
CAS Latency = 3
CAS Latency = 2
CAS Latency = 3
CAS Latency = 2
CAS Latency = 3
CAS Latency = 2
CAS Latency = 3
CAS Latency = 2
CAS Latency = 3
CAS Latency = 2
CAS Latency = 3
CAS Latency = 2
1CLK+t
1CLK+t
1CLK+3—1CLK+3
1CLK
1CLK
Min.
2.5
2.5
60
42
18
16
12
6
8
2
2
0
2
1
2
1
2
1
2
1
1
RP
RP
-6
100,000
Max.
128
5.5
5.5
10
6
6
1CLK+t
1CLK+t
Min.
1CLK
1CLK
8.6
2.5
2.5
2.5
2.5
63
42
20
16
14
7
0
2
1
2
1
2
1
2
1
1
OH
RP
RP
(min.) or V
-7
—1CLK+3
IH
—1CLK+t
—1CLK+t
100,000
(min.) and V
Max.
128
10
6
6
6
6
OL
RP
RP
(max.) when the
Min. Max. Units
1CLK
1CLK
3.5
3.5
2.5
2.5
2.5
2.5
2.5
2.5
10
10
70
50
20
20
20
— ns
— ns
IL
0
1
1
1
1
1
ISSI
(max.).
1-800-379-4774
-10
— ns
100,000 ns
128 ms
10
7
9
7
9
11/01/01
Rev. C
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
®

Related parts for IS42S16100-10TI