Viterbi Byte-Sync control
Once the viterbi lock(VB_NODESYNC) is achieved, the Viterbi decoder
tries to find the byte-sync. This 8-bit register is used to set “unlock-
threshold” for the byte-sync. Large number means it needs more bad-
data to get out of the byte-sync state, i.e. less sensitive to noise. The
default value is 1.