ATEVK1104 Atmel, ATEVK1104 Datasheet - Page 85

KIT DEV/EVAL FOR AVR32 AT32UC3A

ATEVK1104

Manufacturer Part Number
ATEVK1104
Description
KIT DEV/EVAL FOR AVR32 AT32UC3A
Manufacturer
Atmel
Series
AVR®32r
Type
MCUr
Datasheets

Specifications of ATEVK1104

Contents
Evaluation Board, Software and Documentation
Processor To Be Evaluated
AT32UC3A3
Data Bus Width
32 bit
Interface Type
USB, SPI, USART
Silicon Manufacturer
Atmel
Core Architecture
AVR
Core Sub-architecture
AVR UC3
Silicon Core Number
AT32UC3A3256
Silicon Family Name
AVR
Kit Contents
Board CD Docs
Rohs Compliant
Yes
For Use With/related Products
AT32UC3A3
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATEVK1104
Manufacturer:
Atmel
Quantity:
135
13.2.11
13.3
13.3.1
13.3.2
32072C–AVR32–2010/03
Rev. D
MCI
General
Processor and Architecture
1. The busy signal of the responses R1b is not taken in account (excepting for CMD12
1. 3.3V supply monitor is not available on revE.
2. Service access bus (SAB) can not access DMACA registers.
1. LDM instruction with PC in the register list and without ++ increments Rp
2. RETE instruction does not clear SREG[L] from interrupts.
3. Exceptions when system stack is protected by MPU
4. Multiply instructions do not work on RevD.
STOP_TRANSFER).
It is not possible to know the busy status of the card during the response (R1b) for the com-
mands CMD7, CMD28, CMD29, CMD38, CMD42, CMD56.
Fix/Workaround
The card busy line should be polled through the GPIO pin for commands CMD7, CMD28,
CMD29, CMD38, CMD42 and CMD56. The GPIO alternate configuration should be restored
after.
Flash register FGPFRLO[30:29] (FGPFRLO GP29,GP30 and GP31) are reserved and must
not be used.
Fix/workaround
None.
Workaround
None.
For LDM with PC in the register list: the instruction behaves as if the ++ field is always set, ie
the pointer is always updated. This happens even if the ++ field is cleared. Specifically, the
increment of the pointer is done in parallel with the testing of R12.
Fix/Workaround
None.
The RETE instruction clears SREG[L] as expected from exceptions.
Fix/Workaround
When using the STCOND instruction, clear SREG[L] in the stacked value of SR before
returning from interrupts with RETE.
RETS behaves incorrectly when MPU is enabled and MPU is configured so that
system stack is not readable in unprivileged mode.
Fix/Workaround
Workaround 1: Make system stack readable in unprivileged mode,
or
Workaround 2: Return from supervisor mode using rete instead of rets. This requires :
1. Changing the mode bits from 001b to 110b before issuing the instruction.
Updating the mode bits to the desired value must be done using a single mtsr instruction so
it is done atomically. Even if this step is described in general as not safe in the UC technical
reference guide, it is safe in this very specific case.
2. Execute the RETE instruction.
AT32UC3A3/A4
85

Related parts for ATEVK1104