ZLP128ICE01ZEM Zilog, ZLP128ICE01ZEM Datasheet - Page 54
![no-image](/images/manufacturer_photos/0/7/729/zilog_sml.jpg)
ZLP128ICE01ZEM
Manufacturer Part Number
ZLP128ICE01ZEM
Description
EMULATOR CRIMZON Z8 ZLP12840
Manufacturer
Zilog
Datasheets
1.ZLP128ICE01ZEM.pdf
(5 pages)
2.ZLP128ICE01ZEM.pdf
(157 pages)
3.ZLP128ICE01ZEM.pdf
(70 pages)
Specifications of ZLP128ICE01ZEM
Interface Type
RS-232, Ethernet, USB
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
269-3829
- Current page: 54 of 157
- Download datasheet (3Mb)
PS024410-0108
Caution:
Caution:
Transmitting Data Using the Interrupt-Driven Method
6. To transmit additional bytes, return to
7. Before disabling the transmitter, read the transmit completion status bit, UST[1]. If
The UART transmitter interrupt indicates the availability of the Transmit Data register to
accept new data for transmission. Follow the steps below to configure the UART for
interrupt-driven data transmission:
1. Write to the BCNST register to set the appropriate baud rate.
2. Write a 0 to bit 6 of the P01M register.
3. Execute a DI instruction to disable interrupts.
4. Write to the Interrupt control registers to enable the UART Transmitter interrupt and
5. Write to the UART Control register to:
6. Execute an EI instruction to enable interrupts.
7. Because the transmit buffer is empty, an interrupt is immediately executed.
8. Write the data byte to the UART Transmit Data register. The transmitter automatically
9. Execute the IRET instruction to return from the interrupt-service routine and wait for
10. Before disabling the transmitter, read the transmit completion status bit, UST[1]. If
Data written while the transmit enable bit is clear (UCTL[7]=0) will not be transmitted.
Data written while the transmit data status bit is clear (UST[2]=0) overwrites the
previous value written, so the previous written value will not be transmitted. Disabling
the UART transmitter while the transmit completion status bit is clear (UST[1]=0) can
corrupt the byte being transmitted.
Data written while the transmit enable bit is clear (UCTL[7]=0) will not be transmitted.
Data written while the transmit data status bit is clear (UST[2]=0) overwrites the
previous value written, so the previous written value will not be transmitted. Disabling
the UART transmitter while the transmit completion status bit is clear (UST[1]=0) can
corrupt the byte being transmitted.
UST[1]=0, continue to monitor the bit until it changes to 1, which indicates that all
data in the Transmit Data and internal shift registers has been transmitted.
set the appropriate priority.
(a) Set the transmit enable bit (UCTL bit 7) to enable the UART for data transmission.
(b) Enable parity, if appropriate, and select either even or odd parity.
transfers the data to the internal transmit shift register and transmits the data.
the Transmit Data register to again become empty.
UST[1]=0, continue to monitor the bit until it changes to 1, which indicates that all
data in the Transmit Data and internal shift registers has been transmitted.
P R E L I M I N A R Y
step
4.
Universal Asynchronous Receiver/
Product Specification
ZLP12840 OTP MCU
48
Related parts for ZLP128ICE01ZEM
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
![Z8018218FSC](/images/manufacturer_photos/0/7/730/zilog__inc__tmb.jpg)
Part Number:
Description:
Communication Controllers, ZILOG INTELLIGENT PERIPHERAL CONTROLLER (ZIP)
Manufacturer:
Zilog, Inc.
Datasheet:
![Z8F64200100KITG](/photos/9/20/92054/z8f64200100kitg_tmb.jpg)
Part Number:
Description:
KIT DEV FOR Z8 ENCORE 16K TO 64K
Manufacturer:
Zilog
Datasheet:
![Z8F08A28100KITG](/photos/9/22/92241/z8f08a28100kitg_tmb.jpg)
Part Number:
Description:
KIT DEV Z8 ENCORE XP 28-PIN
Manufacturer:
Zilog
Datasheet:
![Z8F08200100KITG](/photos/9/22/92242/z8f08200100kitg_tmb.jpg)
Part Number:
Description:
DEV KIT FOR Z8 ENCORE 8K/4K
Manufacturer:
Zilog
Datasheet:
![Z8F04A28100KITG](/photos/9/22/92243/z8f04a28100kitg_tmb.jpg)
Part Number:
Description:
KIT DEV Z8 ENCORE XP 28-PIN
Manufacturer:
Zilog
Datasheet:
![Z8F08200100KIT](/images/manufacturer_photos/0/7/729/zilog_tmb.jpg)
Part Number:
Description:
DEV KIT FOR Z8 ENCORE 4K TO 8K
Manufacturer:
Zilog
Datasheet:
![Z86C6116FSC](/images/manufacturer_photos/0/7/730/zilog__inc__tmb.jpg)
Part Number:
Description:
CMOS Z8 microcontroller. ROM 16 Kbytes, RAM 256 bytes, speed 16 MHz, 32 lines I/O, 3.0V to 5.5V
Manufacturer:
Zilog, Inc.
Datasheet:
![Z86E0208PSC](/images/manufacturer_photos/0/7/730/zilog__inc__tmb.jpg)
Part Number:
Description:
Low-cost microcontroller. 512 bytes ROM, 61 bytes RAM, 8 MHz
Manufacturer:
Zilog, Inc.
Datasheet:
![Z86E40](/images/manufacturer_photos/0/7/730/zilog__inc__tmb.jpg)
Part Number:
Description:
Z8 4K OTP Microcontroller
Manufacturer:
Zilog, Inc.
Datasheet:
![Z88C0020VEC](/images/manufacturer_photos/0/7/730/zilog__inc__tmb.jpg)
Part Number:
Description:
CMOS SUPER8 ROMLESS MCU
Manufacturer:
Zilog, Inc.
Datasheet:
![Z86E0812SSC](/images/manufacturer_photos/0/7/730/zilog__inc__tmb.jpg)
Part Number:
Description:
SL1866 CMOSZ8 OTP Microcontroller
Manufacturer:
Zilog, Inc.
Datasheet:
![Z86E0812PSC](/images/manufacturer_photos/0/7/730/zilog__inc__tmb.jpg)
Part Number:
Description:
SL1866 CMOSZ8 OTP Microcontroller
Manufacturer:
Zilog, Inc.
Datasheet:
![Z86E0412PSC](/images/manufacturer_photos/0/7/730/zilog__inc__tmb.jpg)
Part Number:
Description:
OTP (KB) = 1, RAM = 125, Speed = 12, I/O = 14, 8-bit Timers = 2, Comm Interfaces Other Features = Por, LV Protect, Voltage = 4.5-5.5V
Manufacturer:
Zilog, Inc.
Datasheet:
![Z9023306PSC](/images/manufacturer_photos/0/7/730/zilog__inc__tmb.jpg)
Part Number:
Description:
Manufacturer:
Zilog, Inc.
Datasheet: