82V2608BB IDT, Integrated Device Technology Inc, 82V2608BB Datasheet - Page 33

no-image

82V2608BB

Manufacturer Part Number
82V2608BB
Description
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of 82V2608BB

Utopia Level
Level 2
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (min)
2.97V
Operating Supply Voltage (max)
3.63V
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Package Type
BGA
Pin Count
208
Mounting
Surface Mount
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
82V2608BB
Manufacturer:
IDT
Quantity:
7
5.3
ters and Command Reply. In the Command Parameters part, a figure is
used to illustrate the byte sequence of the parameters. All the parameter
descriptions are listed below the figure. In the Command Reply part,
another figure is used to illustrate the reply sequence in the reply
message. The reply description is listed below the figure. For detailed
information about the packet of command message and reply message,
refer to
Table-17 ConfigDev Command (Encoding: 01H)
This is the first command to be issued. If this command is not issued, the default value will be used.
Command Parameters
IDT82V2608
PROGRAMMING INFORMATION for IMAOS08
Byte Sequence
Each command description contains two parts: Command Parame-
page
COMMAND DESCRIPTION
1-2
3
4
5
6
7
SysClk
31.
1-2
Parameter Name
TCAlpha&Delta
TCWorkMode
SysClk
T
T
No
exit
in
T
3
in
Default
4E20H
0AH
67H
2H
0H
7H
T
SysClk=Frequency of System Clock (Hz)/1000. For example, if the system clock is 20 MHz, this value
would be 20000.
Unit: sys-ticks in 1 ms (MSB first)
Note: Wrong configuration will make IMAOS’s timer work improperly.
Timer of entering failure alarm state. When a defect persists for a period set by this timer, the
IDT82V2608 will enter failure alarm state.
Unit: 1 s
Timer of exiting failure alarm state. If a defect no longer exists for a period set by this timer, the
IDT82V2608 will exit failure alarm state.
Unit: 1 s
Reserved. Write 0 to this field.
Alpha value is the number of consecutive incorrect HEC fields for the Rx cell synchronization state
machine to exit sync state.
Delta value is the number of consecutive correct HEC fields for the Rx cell synchronization state machine
to enter sync state.
4
exit
Bit Position
Bit Position
7~3
7-4
3-0
2
1
0
33
No
5
Don’t Care
1: Enable Tx TC scrambling (default);
0: Disable Tx TC scrambling
1: Enable Rx TC HEC error correct control (default);
0: Disable Rx TC HEC error correct control
1: Enable Rx TC de-scrambling (default);
0: Disable Rx TC de-scrambling
Delta value. Valid is 0~15.
Alpha value. Valid is 0~15.
TCWorkMode
6
Description
Description
Description
TCAlpha&Delta
Inverse Multiplexing for ATM
7
December 4, 2006
TCLCD_Threshold
8