82V2608BB

Manufacturer Part Number
82V2608BB
Description
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of 82V2608BB

Utopia Level
Level 2
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (min)
2.97V
Operating Supply Voltage (max)
3.63V
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Package Type
BGA
Pin Count
208
Mounting
Surface Mount
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
82V2608BB
Manufacturer:
IDT
Quantity:
7
Table-43 GetConfigPara Command (Encoding: 1CH)
This command is used to get the parameters as shown in the parameter list of a command (designated by Command ID), i.e., get the configured information or default
information as a command’s parameter list designated.
Command Parameters
Command Reply
IDT82V2608
PROGRAMMING INFORMATION for IMAOS08
Byte Sequence
Byte Sequence
4-12
1
2
1
2
3
Command ID sent
Parameter Name
Parameter sent
Group ID sent
Command ID
Command ID
Reply Name
Group ID
before
before
before
Ack
Ack
1
1
The command encoding of the commands below:
Note: If the value is not one from above, IMAOS will work improperly.
The Group ID (If command ID is ‘ConfigDev’, do not care this parameter, that is, any value will do.)
If the command (such as ConfigDev command) has no Group ID parameter, this field should be set to 0 and will be
ignored by the embedded controller.
0: Acknowledge;
1: Invalid parameter;
2: Info not available;
Others: Internal error. The chip should be reset.
Note1: If Ack is not equal to 0, values for the following fields will not be returned.
Note2: If Ack for this command is equal to 0 but the Ack for the command sent before is not equal to 0, values for the
following fields are undetermined.
The command ID sent before.
The Group ID sent before.
For ConfigDev command, this byte has no meaning.
This field contains all the parameters that were sent previously excluding the Group ID, as it is returned in byte 3.
The length of this field depends on the Command ID and the sequence is the same as the input.
Command ID sent before
• ConfigDev
• ConfigUTOPIAIF
• ConfigLoopMode
• ConfigGroupPara
• ConfigGroupInterface
• ConfigGroupWorkMode
• ConfigGSMTimers
• ConfigTRL
• ConfigIFSMpara
Group ID
2
2
Group ID sent before
63
3
Description
Description
Parameter sent before
4-12
Inverse Multiplexing for ATM
December 4, 2006