82V2608BB IDT, Integrated Device Technology Inc, 82V2608BB Datasheet - Page 41

no-image

82V2608BB

Manufacturer Part Number
82V2608BB
Description
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of 82V2608BB

Utopia Level
Level 2
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (min)
2.97V
Operating Supply Voltage (max)
3.63V
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Package Type
BGA
Pin Count
208
Mounting
Surface Mount
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
82V2608BB
Manufacturer:
IDT
Quantity:
7
Table-23 ConfigGSMTimers Command (Encoding: 08H)
Command Parameters
Command Reply
IDT82V2608
PROGRAMMING INFORMATION for IMAOS08
Byte Sequence
Byte Sequence
1
2
3
4
5
1
Parameter Name
Timer for GSM to
Timer for GSM to
report Rx=Active
report Tx=Active
Configure Abort
Timer for GSM
Timer for GSM
Reply Name
start-up Ack
Group ID
Group ID
Ack
Ack
1
1
0: OK;
1: Invalid parameter;
2: The physical group is not configurable;
Others: Internal error. The chip should be reset.
Default
Timer for GSM start-
NA
4H
4H
4H
4H
up Ack
2
Any value is OK. All the groups in the device share the same Timer values.
1~255
Unit: 250 ms
This timer will start when the GSM enters start-up Ack state. If there is no response from the FE after a
period set by this timer, the GSM will return from start-up Ack to start-up state.
If 0 is sent, it will be interpreted as 1*250 ms by the embedded controller.
1~255
Unit: 250 ms
This timer will start when the GSM enters start-up Abort state. After a period set by this timer, the GSM
will return to start-up state.
If 0 is sent, it will be interpreted as 1*250 ms by the embedded controller.
1~255
Unit: 250 ms
This timer will start when all the Rx links are reported Usable. If either all the configured links are being
reported Tx=Usable by the FE or the timer expires, all the Rx links will be brought to Active state.
If 0 is sent, it will be interpreted as 1*250 ms by the embedded controller.
1~255
Unit: 250 ms
This timer will start when all the Tx links are reported Usable. If either all the configured links are being
reported Rx=Active by the FE or the timer expires, all the Tx links will be brought to Active state.
If 0 is sent, it will be interpreted as 1*250 ms by the embedded controller.
Timer for GSM Con-
figure Abort
41
3
Timer for GSM to
report Rx=Active
Description
Description
4
Timer for GSM to
report Tx=Active
Inverse Multiplexing for ATM
5
December 4, 2006