Specifications
U3401A User’s and Service Guide
DC Voltage
DC Current
Table 6-1 DCV resolution, full scale reading and accuracy [±(% of reading + count)]
Range
Table 6-2 DCI resolution, full scale reading and accuracy [± (% of reading + count)]
Range
500 mV
5 V
50 V
500 V
1000 V
500 μA
5 mA
50 mA
500 mA
5 A
10 A
[1]
[2]
[1]
[2]
In 1000 V range, 1200 V is readable with audio warning.
Input impedance is in paralleled with capacitance <100 pF.
Typical at full scale reading and voltage across the input terminals.
In 10 A range, >10-20 Adc is readable for 20 seconds maximum with audio warning.
Resolution
Resolution
10 μV
100 μV
1 mV
10 mV
100 mV
10 nA
100 nA
1 μA
10 μA
100 μA
1 mA
Maximum
reading
Maximum
reading
510.00
5.1000
51.000
510.00
5.1000
20.000
510.00
5.1000
51.000
510.00
1200.0
[2]
[1]
Accuracy
(One year; 23°C ± 5°C)
0.05% + 5
0.05% + 4
0.05% + 4
0.05% + 4
0.25% + 5
0.25% + 5
Specifications and Characteristics
Accuracy
(One year; 23°C ± 5°C)
0.02% + 4
0.02% + 4
0.02% + 4
0.02% + 4
0.02% + 4
Burden voltage
shunt resistor
<0.06 V / 100 Ω
<0.6 V / 100 Ω
<0.08 V / 1 Ω
<0.8 V / 1 Ω
<0.3 V / 0.01 Ω
<0.6 V / 0.01 Ω
Typical input
impedance
10.0 MΩ
11.1 MΩ
10.1 MΩ
10.0 MΩ
10.0 MΩ
[1]
[2]
&