M28529G-12 Mindspeed Technologies, M28529G-12 Datasheet - Page 205

no-image

M28529G-12

Manufacturer Part Number
M28529G-12
Description
ATM IMA 8.192Mbps 1.8V/3.3V 484-Pin BGA
Manufacturer
Mindspeed Technologies
Datasheet

Specifications of M28529G-12

Package
484BGA
Utopia Type
Level 2
Typical Operating Supply Voltage
1.8|3.3 V
Minimum Operating Supply Voltage
1.71|3.135 V
Maximum Operating Supply Voltage
1.89|3.465 V
Maximum Output Rate
8.192 Mbps
2.4.3
This register contains some of the basic IMA Subsystem configuration.
2.4.4
This register contains miscellaneous status information for the IMA Subsystem. Read-only.
28529-DSH-001-K
7–6
5–4
2–0
Bit
Bit
3
7
6
5
4
3
2
1
0
Default
Default
0
0
0
0
0x802—IMA_SUBSYS_CONFIG (IMA Configuration Control)
0x803—IMA_MISC_STATUS (IMA Miscellaneous Status)
Link Type
SRAM size
Number of SRAMs
Number of Ports
ATM Data Width
IMA_RefClk Error
Tx ATM Parity Error
Rx PHY Parity Error
Name
Name
Mindspeed Proprietary and Confidential
Mindspeed Technologies
Sets default link type for all IMA groups. Not used with variable rate facilities
0 = 25 ms (E1 mode)
1 = 50 ms
2 = 100 ms
3 = 200 ms
0 = 1 SRAM, Set to 0 for all M2852x devices
This field indicates the range of valid PHY addresses.
This field has different ranges depending on Product type:
Reserved
Reserved
Reserved
This bit indicates whether the ATM UTOPIA bus is operating in 16 bit (high) or 8 bit (low) data
mode.
This bit is set high if a transition detector for IMA_RefClk detects a bad signal. This bit is active
high and is reset upon reading this address.
This bit indicates that a parity error has been detected on the Transmit ATM side UTOPIA bus.
This bit is active high and is reset upon reading this address.
Reserved.
This bit indicates that a parity error has been detected on the Receive PHY side cell bus. This bit
is active high and is reset upon reading this address.
0 = T1
1 = E1
2 = Alternate T1 (1.544 Mbps payload)
3 = Alternate E1 (1.984 Mbps payload)
0: addresses 0x00–0x03 are valid
1: addresses 0x00–0x07 are valid
2: addresses 0x00–0x0B are valid
3: addresses 0x00–0x0F are valid
4: addresses 0x00–0x13 are valid
5: addresses 0x00–0x17 are valid
6: addresses 0x00–0x1B are valid
7: addresses 0x00–0x1F are valid
M28525: Range: 0–3
M28529: Range: 0–7
®
Description
Description
Registers
190