AD9577BCPZ-R7 Analog Devices Inc, AD9577BCPZ-R7 Datasheet - Page 11

no-image

AD9577BCPZ-R7

Manufacturer Part Number
AD9577BCPZ-R7
Description
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD9577BCPZ-R7

Lead Free Status / Rohs Status
Compliant
Data Sheet
Parameter
LVPECL PERIOD AND CYCLE-TO-CYCLE JITTER (100.12 MHz OUTPUT)
LVDS PERIOD AND CYCLE-TO-CYCLE JITTER (100.12 MHz OUTPUT)
CMOS PERIOD AND CYCLE-TO-CYCLE JITTER (100.12 MHz OUTPUT)
1
2
CMOS REFERENCE CLOCK OUTPUT JITTER
Table 6.
Parameter
JITTER INTEGRATION BANDWIDTH
All period and cycle-to-cycle jitter measurements are made with a Tektronix DPO70604 oscilloscope.
x indicates either 2 or 3 for any given test condition.
Output Peak-to-Peak Period Jitter
Output RMS Period Jitter
Output Peak-to-Peak, Cycle-to-Cycle Jitter
Output RMS Cycle-to-Cycle Jitter
Output Peak-to-Peak Period Jitter
Output RMS Period Jitter
Output Peak-to-Peak, Cycle-to-Cycle Jitter
Output RMS Cycle-to-Cycle Jitter
Output Peak-to-Peak Period Jitter
Output RMS Period Jitter
Output Peak-to-Peak, Cycle-to-Cycle Jitter
Output RMS Cycle-to-Cycle Jitter
12 kHz to 5 MHz
200 kHz to 5 MHz
1
Min
Typ
670
680
Max
1000
950
Rev. 0 | Page 11 of 44
Min
Unit
fs rms
fs rms
Typ
13
2
20
3
17
2
26
4
25
3
36
6
Test Conditions/Comments
Jitter measurement at 25 MHz is equipment limited
25 MHz
Max
Unit
ps p-p
ps rms
ps p-p
ps rms
ps p-p
ps rms
ps p-p
ps rms
ps p-p
ps rms
ps p-p
ps rms
Test Conditions/Comments
25 MHz crystal used, fractional-N
operation, Nb = 100, FRAC = 15,
MOD = 125, Vx = 5, Dx = 5
1,000 cycles, average of 25 measurements
25 MHz crystal used, fractional-N
operation, Nb = 100, FRAC = 15,
MOD = 125, Vx = 5, Dx = 5
1,000 cycles, average of 25 measurements
25 MHz crystal used, 50 Ω load,
fractional-N operation, Nb = 100,
FRAC = 15, MOD = 125, Vx = 5, Dx = 5
1,000 cycles, average of 25 measurements
10,000 cycles, average of 25 measurements
10,000 cycles, average of 25 measurements
1,000 cycles, average of 25 measurements
10,000 cycles, average of 25 measurements
10,000 cycles, average of 25 measurements
1,000 cycles, average of 25 measurements
10,000 cycles, average of 25 measurements
10,000 cycles, average of 25 measurements
1,000 cycles, average of 25 measurements
AD9577
2

Related parts for AD9577BCPZ-R7