CLOCK OUTPUTS
AC coupling capacitors of 0.1 μF used where appropriate.
Table 8.
Parameter
LVPECL CLOCK OUTPUTS
LVDS CLOCK OUTPUTS
CMOS CLOCK OUTPUTS
Output Frequency
Output Voltage Swing, V
Duty Cycle
Output High Voltage, V
Output Low Voltage, V
Output Frequency
Differential Output Voltage, V
Delta V
Duty Cycle
Output Offset Voltage, V
Delta V
Short-Circuit Current, I
Output Frequency
Output High Voltage, V
Output Low Voltage, V
Duty Cycle
OD
OS
OL
OL
SA
OH
OH
, I
OS
OD
SB
OD
Min
610
45
V
V
250
45
1.125
V
45
S
S
S
− 1.24
− 2.07
− 0.15
Rev. 0 | Page 13 of 44
Typ
740
V
V
350
1.25
13
S
S
− 0.94
− 1.75
Max
637.5
950
55
V
V
637.5
475
25
55
1.375
25
24
200
0.1
55
S
S
− 0.83
− 1.62
Unit
MHz
mV
%
V
V
MHz
mV
mV
%
V
mV
mA
MHz
V
V
%
Test Conditions/Comments
Load is 200 Ω to GND at output pins, then
ac-coupled to 50 Ω terminated measurement
equipment.
Load is 200 Ω to GND at output pins, then
ac-coupled to 50 Ω terminated measurement
equipment. For differential amplitude, see
Figure 2.
Load is 200 Ω to GND at output pins, then
ac-coupled to 50 Ω terminated measurement
equipment.
Load is 127 Ω/83 Ω potential divider across
supply dc-coupled into 1 MΩ terminated
measurement equipment, outputs static.
Load is 127 Ω/83 Ω potential divider across
supply dc-coupled into 1 MΩ terminated
measurement equipment, outputs static.
Load is ac-coupled to measurement
equipment that provides 100 Ω differential
input termination.
Load is ac-coupled to measurement
equipment that provides 100 Ω differential
input termination. For differential amplitude,
see Figure 3.
Load is ac-coupled to measurement
equipment that provides 100 Ω differential
input termination.
Load is ac-coupled to measurement
equipment that provides 100 Ω differential
input termination.
Load is dc-coupled to a 100 Ω differential
resistor into 1 MΩ terminated measurement
equipment, outputs static.
Load is dc-coupled to a 100 Ω differential
resistor into 1 MΩ terminated measurement
equipment, outputs static.
Load is dc-coupled to a 100 Ω differential
resistor into 1 MΩ terminated measurement
equipment, output shorted to GND.
Sourcing 1.0 mA current, outputs static.
Sinking 1.0 mA current, outputs static.
Termination is high impedance active probe;
total C
LOAD
= 5 pF, R
LOAD
= 20 kΩ.