SAM7X128 Atmel Corporation, SAM7X128 Datasheet - Page 481

no-image

SAM7X128

Manufacturer Part Number
SAM7X128
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM7X128

Flash (kbytes)
128 Kbytes
Pin Count
100
Max. Operating Frequency
55 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
62
Ext Interrupts
62
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
2
Twi (i2c)
1
Uart
3
Can
1
Ssc
1
Ethernet
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
32
Self Program Memory
NO
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.3
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
• RX_DATA_BK1: Receive Data Bank 1 (only used by endpoints with ping-pong attributes)
This flag generates an interrupt while it is set to one.
Write (Cleared by the firmware):
0 = Notifies USB device that data have been read in the FIFO’s Bank 1.
1 = No effect.
Read (Set by the USB peripheral):
0 = No data packet has been received in the FIFO's Bank 1.
1 = A data packet has been received, it has been stored in FIFO's Bank 1.
When the device firmware has polled this bit or has been interrupted by this signal, it must transfer data from the FIFO to
microcontroller memory. The number of bytes received is available in RXBYTECNT field. Bank 1 FIFO values are read
through UDP_ FDRx register. Once a transfer is done, the device firmware must release Bank 1 to the USB device by
clearing RX_DATA_BK1.
• DIR: Transfer Direction (only available for control endpoints)
Read/Write
0 = Allows Data OUT transactions in the control data stage.
1 = Enables Data IN transactions in the control data stage.
Refer to Chapter 8.5.3 of the Universal Serial Bus Specification, Rev. 2.0 for more information on the control data stage.
This bit must be set before UDP_ CSRx/RXSETUP is cleared at the end of the setup stage. According to the request sent
in the setup data packet, the data stage is either a device to host (DIR = 1) or host to device (DIR = 0) data transfer. It is not
necessary to check this bit to reverse direction for the status stage.
• EPTYPE[2:0]: Endpoint Type
Read/Write
• DTGLE: Data Toggle
Read-only
0 = Identifies DATA0 packet.
1 = Identifies DATA1 packet.
Refer to Chapter 8 of the Universal Serial Bus Specification, Rev. 2.0 for more information on DATA0, DATA1 packet
definitions.
6120I–ATARM–06-Apr-11
000
001
101
010
110
011
111
Control
Isochronous OUT
Isochronous IN
Bulk OUT
Bulk IN
Interrupt OUT
Interrupt IN
SAM7X512/256/128