SAM7X128 Atmel Corporation, SAM7X128 Datasheet - Page 653

no-image

SAM7X128

Manufacturer Part Number
SAM7X128
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM7X128

Flash (kbytes)
128 Kbytes
Pin Count
100
Max. Operating Frequency
55 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
62
Ext Interrupts
62
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
2
Twi (i2c)
1
Uart
3
Can
1
Ssc
1
Ethernet
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
32
Self Program Memory
NO
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.3
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
41.4.9.2
41.4.9.3
41.4.10
41.4.10.1
41.4.10.2
6120I–ATARM–06-Apr-11
Two-wire Interface (TWI)
SSC: Transmitter Limitations in Slave Mode
SSC: Transmitter Limitations in Slave Mode
TWI: Clock Divider
TWI: Disabling Does not Operate Correctly
If TK is programmed as output and TF is programmed as input, it is impossible to emit data
when the start of edge (rising or falling) of synchro has a Start Delay equal to zero.
None.
If TK is programmed as an input and TF is programmed as an output and requested to be set to
low/high during data emission, the Frame Synchro signal is generated one bit clock period after
the data start and one data bit is lost. This problem does not exist when generating a periodic
synchro.
The data need to be delayed for one bit clock period with an external assembly. In the following
schematic, TD, TK and NRST are AT91SAM7X signals, TXD is the delayed data to connect to
the device.
The value of CLDIV x 2
be less than or equal to 8191⋅
None.
Any transfer in progress is immediately frozen if the Control Register (TWI_CR) is written with
the bit MSDIS at 1. Furthermore, the status bits TXCOMP and TXRDY in the Status Register
(TWI_SR) are not reset.
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
CKDIV
must be less than or equal to 8191, the value of CHDIV x 2
SAM7X512/256/128