afbr-820bz Avago Technologies, afbr-820bz Datasheet - Page 29

no-image

afbr-820bz

Manufacturer Part Number
afbr-820bz
Description
Twelve-channel Transmitter And Receiver Pluggable, Parallel-fiber-optic Modules
Manufacturer
Avago Technologies
Datasheet
29
Address
Byte
24
24
24
24
24
24
25
25
25
25
25
25
26
26
26
26
26
26
27
27
27
27
27
27
28
29
30-31
32-33
34-35
36-39
40-41
42-43
44-45
46-47
48-49
50-51
52-53
54-55
56-57
58-59
Bit
7
6
5-4
3
2
1-0
7
6
5-4
3
2
1-0
7
6
5-4
3
2
1-0
7
6
5-4
3
2
1-0
all
all
all
all
all
all
all
all
all
all
all
all
all
all
all
all
Type
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
Field Name/Description
High Tx Power Alarm Latched Channel 7: Coded 1 when asserted, Latched, Clears on Read.
Low Tx Power Alarm Latched Channel 7: Coded 1 when asserted, Latched, Clears on Read.
Reserved
High Tx Power Alarm Latched Channel 6: Coded 1 when asserted, Latched, Clears on Read.
Low Tx Power Alarm Latched Channel 6: Coded 1 when asserted, Latched, Clears on Read.
Reserved
High Tx Power Alarm Latched Channel 5: Coded 1 when asserted, Latched, Clears on Read.
Low Tx Power Alarm Latched Channel 5: Coded 1 when asserted, Latched, Clears on Read.
Reserved
High Tx Power Alarm Latched Channel 4: Coded 1 when asserted, Latched, Clears on Read.
Low Tx Power Alarm Latched Channel 4: Coded 1 when asserted, Latched, Clears on Read.
Reserved
High Tx Power Alarm Latched Channel 3: Coded 1 when asserted, Latched, Clears on Read.
Low Tx Power Alarm Latched Channel 3: Coded 1 when asserted, Latched, Clears on Read.
Reserved
High Tx Power Alarm Latched Channel 2: Coded 1 when asserted, Latched, Clears on Read.
Low Tx Power Alarm Latched Channel 2: Coded 1 when asserted, Latched, Clears on Read.
Reserved
High Tx Power Alarm Latched Channel 1: Coded 1 when asserted, Latched, Clears on Read.
Low Tx Power Alarm Latched Channel 1: Coded 1 when asserted, Latched, Clears on Read.
Reserved
High Tx Power Alarm Latched Channel 0: Coded 1 when asserted, Latched, Clears on Read.
Low Tx Power Alarm Latched Channel 0: Coded 1 when asserted, Latched, Clears on Read.
Reserved
Internal Temperature Monitor MSB: Integer part coded in signed 2’s complement. Tolerance is ± 3°C.
Internal Temperature Monitor LSB: Fractional part in units of 1°/256 coded in binary.
Reserved: Coded 00h
Internal 3.3 Vcc Monitor: Voltage in 100 μV units coded as 16 bit unsigned integer, Byte 32 is MSB. Tolerance is
± 0.150V.
Internal 2.5 Vcc Monitor: Voltage in 100 μV units coded as 16 bit unsigned integer, Byte 34 is MSB. Tolerance is
± 0.150V.
Reserved: Coded 00h
Tx Bias Current Monitor Channel 11: Bias current in 2 PA units coded as 16 bit unsigned integer, Byte 40 is MSB.
Tolerance is ± 0.50 mA.
Tx Bias Current Monitor Channel 10: Bias current in 2 PA units coded as 16 bit unsigned integer, Byte 42 is MSB.
Tolerance is ± 0.50 mA.
Tx Bias Current Monitor Channel 9: Bias current in 2 PA units coded as 16 bit unsigned integer, Byte 44 is MSB.
Tolerance is ± 0.50 mA.
Tx Bias Current Monitor Channel 8: Bias current in 2 PA units coded as 16 bit unsigned integer, Byte 46 is MSB.
Tolerance is ± 0.50 mA.
Tx Bias Current Monitor Channel 7: Bias current in 2 PA units coded as 16 bit unsigned integer, Byte 48 is MSB.
Tolerance is ± 0.50 mA.
Tx Bias Current Monitor Channel 6: Bias current in 2 PA units coded as 16 bit unsigned integer, Byte 50 is MSB.
Tolerance is ± 0.50 mA.
Tx Bias Current Monitor Channel 5: Bias current in 2 PA units coded as 16 bit unsigned integer, Byte 52 is MSB.
Tolerance is ± 0.50 mA.
Tx Bias Current Monitor Channel 4: Bias current in 2 PA units coded as 16 bit unsigned integer, Byte 54 is MSB.
Tolerance is ± 0.50 mA.
Tx Bias Current Monitor Channel 3: Bias current in 2 PA units coded as 16 bit unsigned integer, Byte 56 is MSB.
Tolerance is ± 0.50 mA.
Tx Bias Current Monitor Channel 2: Bias current in 2 P A units coded as 16 bit unsigned integer, Byte 58 is MSB.
Tolerance is ± 0.50 mA.