afbr-820bz Avago Technologies, afbr-820bz Datasheet - Page 38

no-image

afbr-820bz

Manufacturer Part Number
afbr-820bz
Description
Twelve-channel Transmitter And Receiver Pluggable, Parallel-fiber-optic Modules
Manufacturer
Avago Technologies
Datasheet
38
Address
Byte
24
24
24
24
24
24
25
25
25
25
25
25
26
26
26
26
26
26
27
27
27
27
27
27
28
29
30-31
32-33
34-35
36-63
64-65
66-67
68-69
70-71
72-73
74-75
76-77
78-79
Bit
7
6
5-4
3
2
1-0
7
6
5-4
3
2
1-0
7
6
5-4
3
2
1-0
7
6
5-4
3
2
1-0
all
all
all
all
all
all
all
all
all
all
all
all
all
all
Type
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
Field Name/Description
High Rx Power Alarm Latched Channel 7: Coded 1 when asserted, Latched, Clears on Read.
Low Rx Power Alarm Latched Channel 7: Coded 1 when asserted, Latched, Clears on Read.
Reserved
High Rx Power Alarm Latched Channel 6: Coded 1 when asserted, Latched, Clears on Read.
Low Rx Power Alarm Latched Channel 6: Coded 1 when asserted, Latched, Clears on Read.
Reserved
High Rx Power Alarm Latched Channel 5: Coded 1 when asserted, Latched, Clears on Read.
Low Rx Power Alarm Latched Channel 5: Coded 1 when asserted, Latched, Clears on Read.
Reserved
High Rx Power Alarm Latched Channel 4: Coded 1 when asserted, Latched, Clears on Read.
Low Rx Power Alarm Latched Channel 4: Coded 1 when asserted, Latched, Clears on Read.
Reserved
High Rx Power Alarm Latched Channel 3: Coded 1 when asserted, Latched, Clears on Read.
Low Rx Power Alarm Latched Channel 3: Coded 1 when asserted, Latched, Clears on Read.
Reserved
High Rx Power Alarm Latched Channel 2: Coded 1 when asserted, Latched, Clears on Read.
Low Rx Power Alarm Latched Channel 2: Coded 1 when asserted, Latched, Clears on Read.
Reserved
High Rx Power Alarm Latched Channel 1: Coded 1 when asserted, Latched, Clears on Read.
Low Rx Power Alarm Latched Channel 1: Coded 1 when asserted, Latched, Clears on Read.
Reserved
High Rx Power Alarm Latched Channel 0: Coded 1 when asserted, Latched, Clears on Read.
Low Rx Power Alarm Latched Channel 01: Coded 1 when asserted, Latched, Clears on Read.
Reserved
Internal Temperature Monitor MSB: Integer part coded in signed 2’s complement. Tolerance is ± 3°C.
Internal Temperature Monitor LSB: Fractional part in units of 1°/256 coded in binary.
Reserved: Coded 00h
Internal 3.3 Vcc Monitor: Voltage in 100 μV units coded as 16 bit unsigned integer, Byte 32 is MSB. Tolerance is
± 0.150V.
Internal 2.5 Vcc Monitor: Voltage in 100 μV units coded as 16 bit unsigned integer, Byte 34 is MSB. Tolerance is
± 0.150V.
Reserved: Coded 00h
Rx Optical Input, Pave, Monitor Channel 11: Optical power in 0.1 PW units coded as 16 bit unsigned integer, Byte
64 is MSB. Tolerance is ± 3dB for -10 dBm to -1.0 dBm range.
Rx Optical Input, Pave, Monitor Channel 10: Optical power in 0.1 PW units coded as 16 bit unsigned integer, Byte
66 is MSB. Tolerance is ± 3dB for -10 dBm to -1.0 dBm range.
Rx Optical Input, Pave, Monitor Channel 9: Optical power in 0.1 PW units coded as 16 bit unsigned integer, Byte 68
is MSB. Tolerance is ± 3dB for -10 dBm to -1.0 dBm range.
Rx Optical Input, Pave, Monitor Channel 8: Optical power in 0.1 PW units coded as 16 bit unsigned integer, Byte 70
is MSB. Tolerance is ± 3dB for -10 dBm to -1.0 dBm range.
Rx Optical Input, Pave, Monitor Channel 7: Optical power in 0.1 PW units coded as 16 bit unsigned integer, Byte 72
is MSB. Tolerance is ± 3dB for -10 dBm to -1.0 dBm range.
Rx Optical Input, Pave, Monitor Channel 6: Optical power in 0.1 PW units coded as 16 bit unsigned integer, Byte 74
is MSB. Tolerance is ± 3dB for -10 dBm to -1.0 dBm range.
Rx Optical Input, Pave, Monitor Channel 5: Optical power in 0.1 PW units coded as 16 bit unsigned integer, Byte 76
is MSB. Tolerance is ± 3dB for -10 dBm to -1.0 dBm range.
Rx Optical Input, Pave, Monitor Channel 4: Optical power in 0.1 PW units coded as 16 bit unsigned integer, Byte 78
is MSB. Tolerance is ± 3dB for -10 dBm to -1.0 dBm range.