afbr-820bz Avago Technologies, afbr-820bz Datasheet - Page 39

no-image

afbr-820bz

Manufacturer Part Number
afbr-820bz
Description
Twelve-channel Transmitter And Receiver Pluggable, Parallel-fiber-optic Modules
Manufacturer
Avago Technologies
Datasheet
39
Address
Byte
80-81
82-83
84-85
86-87
88-89
90
91
91
92
92
92
92
92
93
93
93
93
93
93
93
93
94
94
94
94
94
95
95
95
95
95
95
95
95
96
96
96
96
97
97
97
97
Bit
all
all
all
all
all
all
7-1
0
7-4
3
2
1
0
7
6
5
4
3
2
1
0
7-4
3
2
1
0
7
6
5
4
3
2
1
0
7-6
5-4
3-2
1-0
7-6
5-4
3-2
1-0
Type
RO
RO
RO
RO
RO
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
Field Name/Description
Rx Optical Input, Pave, Monitor Channel 3: Optical power in 0.1 PW units coded as 16 bit unsigned integer, Byte 80
is MSB. Tolerance is ± 3dB for -10 dBm to -1.0 dBm range.
Rx Optical Input, Pave, Monitor Channel 2: Optical power in 0.1 PW units coded as 16 bit unsigned integer, Byte 82
is MSB. Tolerance is ± 3dB for -10 dBm to -1.0 dBm range.
Rx Optical Input, Pave, Monitor Channel 1: Optical power in 0.1 PW units coded as 16 bit unsigned integer, Byte 84
is MSB. Tolerance is ± 3dB for -10 dBm to -1.0 dBm range.
Rx Optical Input, Pave, Monitor Channel 0: Optical power in 0.1 PW units coded as 16 bit unsigned integer, Byte 86
is MSB. Tolerance is ± 3dB for -10 dBm to -1.0 dBm range.
Elapsed (Power-on) Operating Time: Elapsed time in 2 hour units coded as 16 bit unsigned integer, Byte 88 is MSB,
Tolerance is ± 10%
Reserved: Coded 00h
Reserved: Coded 0000000b
Receiver Reset: Writing 1 return all registers except non-volatile RW to factory default values. Reads 0 after
operation.
Reserved: Coded 0000b
Rx Channel 11 Disable: Writing 1 deactivates the electrical output, Default is 0.
Rx Channel 10 Disable: Writing 1 deactivates the electrical output, Default is 0.
Rx Channel 9 Disable: Writing 1 deactivates the electrical output, Default is 0.
Rx Channel 8 Disable: Writing 1 deactivates the electrical output, Default is 0.
Rx Channel 7 Disable: Writing 1 deactivates the electrical output, Default is 0.
Rx Channel 6 Disable: Writing 1 deactivates the electrical output, Default is 0.
Rx Channel 5 Disable: Writing 1 deactivates the electrical output, Default is 0.
Rx Channel 4 Disable: Writing 1 deactivates the electrical output, Default is 0.
Rx Channel 3 Disable: Writing 1 deactivates the electrical output, Default is 0.
Rx Channel 2 Disable: Writing 1 deactivates the electrical output, Default is 0.
Rx Channel 1 Disable: Writing 1 deactivates the electrical output, Default is 0.
Rx Channel 0 Disable: Writing 1 deactivates the electrical output, Default is 0.
Reserved: Coded 0000b
Squelch Disable Channel 11: Writing 1 inhibits squelch for the channel, Default is 0.
Squelch Disable Channel 10: Writing 1 inhibits squelch for the channel, Default is 0.
Squelch Disable Channel 9: Writing 1 inhibits squelch for the channel, Default is 0.
Squelch Disable Channel 8: Writing 1 inhibits squelch for the channel, Default is 0.
Squelch Disable Channel 7: Writing 1 inhibits squelch for the channel, Default is 0.
Squelch Disable Channel 6: Writing 1 inhibits squelch for the channel, Default is 0.
Squelch Disable Channel 5: Writing 1 inhibits squelch for the channel, Default is 0.
Squelch Disable Channel 4: Writing 1 inhibits squelch for the channel, Default is 0.
Squelch Disable Channel 3: Writing 1 inhibits squelch for the channel, Default is 0.
Squelch Disable Channel 2: Writing 1 inhibits squelch for the channel, Default is 0.
Squelch Disable Channel 1: Writing 1 inhibits squelch for the channel, Default is 0.
Squelch Disable Channel 0: Writing 1 inhibits squelch for the channel, Default is 0.
Rate Select Channel 11: Write 00 for max. BW, 01 for SDR BW, rest reserved. Default is 00
Rate Select Channel 10: Write 00 for max. BW, 01 for SDR BW, rest reserved. Default is 00
Rate Select Channel 9: Write 00 for max. BW, 01 for SDR BW, rest reserved. Default is 00
Rate Select Channel 8: Write 00 for max. BW, 01 for SDR BW, rest reserved. Default is 00
Rate Select Channel 7: Write 00 for max. BW, 01 for SDR BW, rest reserved. Default is 00
Rate Select Channel 6: Write 00 for max. BW, 01 for SDR BW, rest reserved. Default is 00
Rate Select Channel 5: Write 00 for max. BW, 01 for SDR BW, rest reserved. Default is 00
Rate Select Channel 4: Write 00 for max. BW, 01 for SDR BW, rest reserved. Default is 00

Related parts for afbr-820bz