6. Rx Memory Map 5ih Lower Page
Details of the base or lower page of the memory map for a receiver follow.
37
Address
Byte
0
1
2
2
2
2
3 - 7
8
9
9
9
9
9
10
10
10
10
10
10
10
10
11-12
13
13
13
14
14
14
14
14
14
15-21
22
22
22
22
22
22
23
23
23
23
23
23
Bit
all
all
7-3
2
1
0
all
0
7-4
3
2
1
0
7
6
5
4
3
2
1
0
all
7
6
5-0
7
6
5-4
3
2
1-0
all
7
6
5-4
3
2
1-0
7
6
5-4
3
2
1-0
Type
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
Field Name/Description
Type Identifier: Coded 00h for unspecified
Reserved: Coded 00h
Reserved: Coded 000000b
LOS Status: Coded 1 when a LOS flag (bytes 9 and 10 of this page) is asserted for any channel, else 0. Clears when
LOS flags are cleared.
IntL Status: Coded 1 for asserted IntL. Clears to 0 when all flags including LOS are cleared.
Data Not Ready: Coded 1 until data is available in monitor registers. Coded 0 in normal operation.
Reserved: Coded 00h
Module Ready Interrupt. Coded 1 when asserted and module is Ready to respond to TWS commands, Latched,
Clears on Read.
Reserved: Coded 0000b
LOS Latched Rx Channel 11: Coded 1 when asserted, Latched, Clears on Read.
LOS Latched Rx Channel 10: Coded 1 when asserted, Latched, Clears on Read.
LOS Latched Rx Channel 9: Coded 1 when asserted, Latched, Clears on Read.
LOS Latched Rx Channel 8: Coded 1 when asserted, Latched, Clears on Read.
LOS Latched Rx Channel 7: Coded 1 when asserted, Latched, Clears on Read.
LOS Latched Rx Channel 6: Coded 1 when asserted, Latched, Clears on Read.
LOS Latched Rx Channel 5: Coded 1 when asserted, Latched, Clears on Read.
LOS Latched Rx Channel 4: Coded 1 when asserted, Latched, Clears on Read.
LOS Latched Rx Channel 3: Coded 1 when asserted, Latched, Clears on Read.
LOS Latched Rx Channel 2: Coded 1 when asserted, Latched, Clears on Read.
LOS Latched Rx Channel 1: Coded 1 when asserted, Latched, Clears on Read.
LOS Latched Rx Channel 0: Coded 1 when asserted, Latched, Clears on Read.
Reserved: Coded 00h
High Internal Temperature Alarm Latched: Coded 1 when asserted, Latched, Clears on Read.
Low Internal Temperature Alarm Latched: Coded 1 when asserted, Latched, Clears on Read.
Reserved
High Internal 3.3 Vcc Alarm Latched: Coded 1 when asserted, Latched, Clears on Read.
Low Internal 3.3 Vcc Alarm Latched: Coded 1 when asserted, Latched, Clears on Read.
Reserved
High Internal 2.5 Vcc Alarm Latched: Coded 1 when asserted, Latched, Clears on Read.
Low Internal 2.5 Vcc Alarm Latched: Coded 1 when asserted, Latched, Clears on Read.
Reserved
Reserved: Coded 00h
High Rx Power Alarm Latched Channel 11: Coded 1 when asserted, Latched, Clears on Read.
Low Rx Power Alarm Latched Channel 11: Coded 1 when asserted, Latched, Clears on Read.
Reserved
High Rx Power Alarm Latched Channel 10: Coded 1 when asserted, Latched, Clears on Read.
Low Rx Power Alarm Latched Channel 10: Coded 1 when asserted, Latched, Clears on Read.
Reserved
High Rx Power Alarm Latched Channel 9: Coded 1 when asserted, Latched, Clears on Read.
Low Rx Power Alarm Latched Channel 9: Coded 1 when asserted, Latched, Clears on Read.
Reserved
High Rx Power Alarm Latched Channel 8: Coded 1 when asserted, Latched, Clears on Read.
Low Rx Power Alarm Latched Channel 8: Coded 1 when asserted, Latched, Clears on Read.
Reserved