P80C554SFBD,157 NXP Semiconductors, P80C554SFBD,157 Datasheet - Page 46

IC 80C51 MCU 8BIT ROMLESS 64LQFP

P80C554SFBD,157

Manufacturer Part Number
P80C554SFBD,157
Description
IC 80C51 MCU 8BIT ROMLESS 64LQFP
Manufacturer
NXP Semiconductors
Series
80Cr
Datasheet

Specifications of P80C554SFBD,157

Core Processor
8051
Core Size
8-Bit
Speed
16MHz
Connectivity
EBI/EMI, I²C, UART/USART
Peripherals
POR, PWM, WDT
Number Of I /o
40
Program Memory Type
ROMless
Ram Size
512 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 7x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
64-LQFP
Processor Series
P80C5x
Core
80C51
Data Bus Width
8 bit
Data Ram Size
512 B
Interface Type
I2C, UART
Maximum Clock Frequency
8 MHz, 16 MHz
Number Of Programmable I/os
40
Number Of Timers
3
Operating Supply Voltage
2.7 V to 5.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
PK51, CA51, A51, ULINK2
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 7 Channel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-
Lead Free Status / Rohs Status
 Details
Other names
568-2086
935268881157
P80C554SFBD

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P80C554SFBD,157
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Philips Semiconductors
Table 8.
2003 Jan 28
STATUS
STATUS
(S1STA)
(S1STA)
CODE
80C51 8-bit microcontroller – 6-clock operation
16K/512 OTP/ROMless, 7 channel 10 bit A/D, I
high I/O, 64L LQFP
60H
68H
70H
78H
80H
88H
90H
98H
Own SLA+W has
been received; ACK
h
has been returned
Arbitration lost in
SLA+R/W as master;
Own SLA+W has
b
been received, ACK
returned
General call address
(00H) has been
received; ACK has
received ACK has
been returned
Arbitration lost in
SLA+R/W as master;
General call address
has been received
has been received,
ACK has been
returned
Previously addressed
with own SLV
address; DATA has
b
been received; ACK
has been returned
Previously addressed
with own SLA; DATA
b
byte has been
received; NOT ACK
has been returned
Previously addressed
with General Call;
DATA byte has been
received; ACK has
been returned
Previously addressed
with General Call;
DATA b
DATA byte has been
received; NOT ACK
has been returned
SIO1 HARDWARE
SIO1 HARDWARE
STATUS OF THE
STATUS OF THE
Slave Receiver Mode
I
b
i
2
h
C BUS AND
d ACK h
b
i
i
h
d ACK
d ACK
b
d
No S1DAT action or
no S1DAT action
No S1DAT action or
no S1DAT action
No S1DAT action or
no S1DAT action
No S1DAT action or
no S1DAT action
Read data byte or
read data byte
Read data byte or
read data byte or
read data byte or
read data byte
Read data byte or
read data byte
Read data byte or
read data byte or
read data byte or
read data byte
TO/FROM S1DAT
TO/FROM S1DAT
APPLICATION SOFTWARE RESPONSE
STA
X
X
X
X
X
X
X
X
X
X
X
X
0
0
1
1
0
0
1
1
TO S1CON
STO
2
C, PWM, capture/compare,
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
46
SI
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
AA
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Data byte will be received and NOT ACK will be
returned
Data byte will be received and ACK will be returned
Data byte will be received and NOT ACK will be
returned
Data byte will be received and ACK will be returned
Data byte will be received and NOT ACK will be
returned
Data byte will be received and ACK will be returned
Data byte will be received and NOT ACK will be
returned
Data byte will be received and ACK will be returned
Data byte will be received and NOT ACK will be
returned
Data byte will be received and ACK will be returned
Switched to not addressed SLV mode; no recognition
of own SLA or General call address
Switched to not addressed SLV mode; Own SLA will
be recognized; General call address will be
recognized if S1ADR.0 = logic 1
Switched to not addressed SLV mode; no recognition
of own SLA or General call address. A START
condition will be transmitted when the bus becomes
free
Switched to not addressed SLV mode; Own SLA will
be recognized; General call address will be
recognized if S1ADR.0 = logic 1. A START condition
will be transmitted when the bus becomes free.
Data byte will be received and NOT ACK will be
returned
Data byte will be received and ACK will be returned
Switched to not addressed SLV mode; no recognition
of own SLA or General call address
Switched to not addressed SLV mode; Own SLA will
be recognized; General call address will be
recognized if S1ADR.0 = logic 1
Switched to not addressed SLV mode; no recognition
of own SLA or General call address. A START
condition will be transmitted when the bus becomes
free
Switched to not addressed SLV mode; Own SLA will
be recognized; General call address will be
recognized if S1ADR.0 = logic 1. A START condition
will be transmitted when the bus becomes free.
NEXT ACTION TAKEN BY SIO1 HARDWARE
80C554/87C554
Product data

Related parts for P80C554SFBD,157