Z8F012ASB020SG Zilog, Z8F012ASB020SG Datasheet - Page 83

IC ENCORE XP MCU FLASH 1K 8SOIC

Z8F012ASB020SG

Manufacturer Part Number
Z8F012ASB020SG
Description
IC ENCORE XP MCU FLASH 1K 8SOIC
Manufacturer
Zilog
Series
Encore!® XP®r
Datasheet

Specifications of Z8F012ASB020SG

Core Processor
Z8
Core Size
8-Bit
Speed
20MHz
Connectivity
IrDA, UART/USART
Peripherals
Brown-out Detect/Reset, LED, LVD, POR, PWM, Temp Sensor, WDT
Number Of I /o
6
Program Memory Size
1KB (1K x 8)
Program Memory Type
FLASH
Eeprom Size
16 x 8
Ram Size
256 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 4x10b
Oscillator Type
Internal
Operating Temperature
0°C ~ 70°C
Package / Case
8-SOIC (3.9mm Width)
Processor Series
Z8F012Ax
Core
eZ8
Data Bus Width
8 bit
Data Ram Size
256 B
Interface Type
UART
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
6
Number Of Timers
2
Operating Supply Voltage
2.7 V to 3.6 V
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Development Tools By Supplier
Z8F04A08100KITG, Z8F04A28100KITG, ZENETSC0100ZACG, ZENETSC0100ZACG, ZUSBOPTSC01ZACG, ZUSBSC00100ZAC, ZUSBSC00100ZACG
Minimum Operating Temperature
0 C
On-chip Adc
10 bit, 4 Channel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
269-4039
Z8F012ASB020SG
PS022825-0908
Caution:
2. Write to the Timer High and Low Byte registers to set the starting count value (usually
3. Write to the Timer Reload High and Low Byte registers to set the Reload value.
4. Enable the timer interrupt (if appropriate) and set the timer interrupt priority by
5. Configure the associated GPIO port pin (if using the Timer Output function) for the
6. Write to the Timer Control register to enable the timer and initiate counting.
In CONTINUOUS mode, the system clock always provides the timer input. The timer
period is given by the following equation:
If an initial starting value other than
registers, use the ONE-SHOT mode equation to determine the first time-out period.
COUNTER Mode
In COUNTER mode, the timer counts input transitions from a GPIO port pin. The timer
input is taken from the GPIO Port pin Timer Input alternate function. The TPOL bit in the
Timer Control Register selects whether the count occurs on the rising edge or the falling
edge of the Timer Input signal. In COUNTER mode, the prescaler is disabled.
Upon reaching the Reload value stored in the Timer Reload High and Low Byte registers,
the timer generates an interrupt, the count value in the Timer High and Low Byte registers
is reset to
enabled, the Timer Output pin changes state (from Low to High or from High to Low) at
timer Reload.
The input frequency of the Timer Input signal must not exceed one-fourth the system
clock frequency. Further, the high or low state of the input signal pulse must be no less
than twice the system clock period. A shorter pulse may not be captured.
0001H). This action only affects the first pass in CONTINUOUS mode. After the first
timer Reload in CONTINUOUS mode, counting always begins at the reset value of
0001H
writing to the relevant interrupt registers.
Timer Output alternate function.
CONTINUOUS Mode Time-Out Period (s)
Set the prescale value.
If using the Timer Output alternate function, set the initial output level (High or
Low).
0001H
.
and counting resumes. Also, if the Timer Output alternate function is
0001H
is loaded into the Timer High and Low Byte
=
----------------------------------------------------------------------- -
System Clock Frequency (Hz)
Reload Value Prescale
Z8 Encore! XP
Product Specification
×
®
F082A Series
Timers
72