Specifications of SAF-XC878CM-16FFI

Controller Family/series
XC800
Core Size
8bit
Program Memory Size
64KB
Ram Memory Size
3328Byte
No. Of Timers
4
No. Of Pwm Channels
10
Digital Ic Case Style
LQFP
Supply Voltage Range
4.5V To
Peripherals
ADC, PWM, Timer
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SAF-XC878CM-16FFI 3V3 AA
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
SAF-XC878CM-16FFI 3V3 AC
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
SAF-XC878CM-16FFI 5V AA
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
SAF-XC878CM-16FFI 5V AA
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
SAF-XC878CM-16FFI 5V AC
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
SAF-XC878CM-16FFI5VAC
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Figure 9
In order to access a register located in a page different from the actual one, the current
page must be exited. This is done by reprogramming the bit field PAGE in the page
register. Only then can the desired access be performed.
If an interrupt routine is initiated between the page register access and the module
register access, and the interrupt needs to access a register located in another page, the
current page setting can be saved, the new one programmed and the old page setting
restored. This is possible with the storage fields STx (x = 0 - 3) for the save and restore
action of the current page setting. By indicating which storage bit field should be used in
parallel with the new page value, a single write operation can:
Data Sheet
Save the contents of PAGE in STx before overwriting with the new value
(this is done in the beginning of the interrupt routine to save the current page setting
and program the new page number); or
Address Extension by Paging
(to/from CPU)
SFR Address
(from CPU)
SFR Data
rw
MOD_PAGE.PAGE
27
Module
SFR0
SFR1
SFRx
SFR0
SFR1
SFRy
SFR0
SFR1
SFRz
Functional Description
PAGE 0
PAGE 1
PAGE q
XC878CLM
V1.2, 2009-11