EP9315-IBZ Cirrus Logic Inc, EP9315-IBZ Datasheet - Page 393

32-Bit Microcontroller IC

EP9315-IBZ

Manufacturer Part Number
EP9315-IBZ
Description
32-Bit Microcontroller IC
Manufacturer
Cirrus Logic Inc
Series
EP9r
Datasheets

Specifications of EP9315-IBZ

Controller Family/series
(ARM9)
Core Size
32 Bit
A/d Converter
12 Bits
Supply Voltage
3.3V
No. Of I/o Pins
65
Package / Case
352-PBGA
Clock Frequency
200MHz
Core Processor
ARM9
Speed
200MHz
Connectivity
EBI/EMI, EIDE, Ethernet, I²C, IrDA, Keypad/Touchscreen, PCMCIA, SPI, UART/USART, USB
Peripherals
AC'97, DMA, I&sup2:S, LCD, LED, MaverickKey, POR, PWM, WDT
Number Of I /o
16
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.65 V ~ 3.6 V
Data Converters
A/D 8x12b
Oscillator Type
External
Operating Temperature
-40°C ~ 85°C
Processor Series
EP93xx
Core
ARM920T
Data Bus Width
32 bit
3rd Party Development Tools
MDK-ARM, RL-ARM, ULINK2
Development Tools By Supplier
EDB9315A-Z
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
598-1144 - KIT DEVELOPMENT EP9315 ARM9
Eeprom Size
-
Program Memory Size
-
Lead Free Status / Rohs Status
 Details
Other names
598-1263

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP9315-IBZ
Manufacturer:
CIRRUS
Quantity:
13
Part Number:
EP9315-IBZ
Manufacturer:
CIRRUS
Quantity:
347
Part Number:
EP9315-IBZ
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
MaxFrmLen
DS785UM1
31
15
Address:
Chip Reset:
Soft Reset:
Definition:
Bit Descriptions:
30
14
RSVD
RSVD
29
13
28
12
TDST:
0x8001_00E8 - Read/Write
0x0000_0000
Unchanged
Maximum Frame Length and Transmit Start Threshold register.
RSVD:
MFL:
27
11
26
10
Copyright 2007 Cirrus Logic
25
9
Transmit Descriptor Soft Threshold.
The hard and soft threshold work in exactly the same
manner except one. The soft threshold will not cause a
bus request to be made if the bus is currently in use, but
only when it is deemed to be idle (no transfers for four
AHB clocks). The hard threshold takes effect immediately
regardless of the state of the bus. This operation allows for
more efficient use of the AHB bus by allowing smaller
transfers to take place when the bus is lightly loaded and
requesting larger transfers only when the bus is more
heavily loaded.
Reserved. Unknown During Read.
Maximum Frame Length. The maximum frame length is a
limit for the amount of data permitted to be transferred
across the AHB bus for a transmit frame, or on the wire for
a receive frame. When this limit is reached for a transmit
frame, the Transmit Descriptor Processor is halted and a
transmit length error is set in the Interrupt Status register.
When the limit is reached for a receive frame, no further
data will be transferred to memory for the current frame.
The status written for the frame will indicate the length
error, and further frames will continue as normal, (the
Receive Descriptor Processor will not halt).
24
8
23
7
22
6
MFL
TST
21
1/10/100 Mbps Ethernet LAN Controller
5
20
4
19
3
EP93xx User’s Guide
18
2
17
1
16
9-91
0
9