CV-mode Commands for PCs
6-5-17 FORCED SET/RESET
Command Block
Response Block
Parameters
23
Command
code
01
bits/flags
No. of
Note
specification
Set/Reset
No. of comments (command): If the block contains comments data, indicate
the number of comments in this byte.
Block no. (command): The block number of the block to which data will be writ-
ten. The block no. must be between 0000 and 03E7 (0 to 999 decimal) for 1000
block file memory, or 0000 and 07CF (0 to 1999 decimal) for 2000 block file
memory.
Data (command): The 256 bytes of data that will be written to the indicated
block.
Force-sets (ON) or force-resets (OFF) bits/flags or releases forced status. Bits/
flags that are forced ON or OFF will remain ON or OFF and cannot be written to
until the forced status is released, e.g., by using this command.
No. of bits/flags (command): The number of bits/flags to be forced set/reset or
released.
Set/Reset specification (command): The action to be taken for each bit/flag
Memory area code (command): The memory area of the bit or flag to be con-
trolled.
Bit/Flag (command): The bit or flag to be controlled.
0000
0001
8000
8001
FFFF
Command
1. In the C1000H and C2000H, only the Force-reset (0000) and Force-set
2. In the C200H/C200Hj, two or more bits can be force set/reset. (Forced sta-
3. The Forced status released and bit turned OFF (8000) and Forced status
23
Value
code
Forced set/reset data
(0001) actions can be specified. Furthermore, only one bit can be force set/
reset at a time. If force set/reset data for more than one bit is included in the
command, only the last bit will be force set/reset. The forced status of the
other bits/flags in the command will be released.
tus will be maintained unless a forced status release action is performed.)
released and bit turned ON (8001) actions cannot be performed on timer/
counter Completion Flags. If these actions are specified, they revert to the
Force-reset (0000) and Force-set (0001) actions, respectively.
01
Memory area code
Force-reset (OFF)
Force-set (ON)
Forced status released and bit turned OFF (0)
Forced status released and bit turned ON (1)
Forced status released
Response
code
Bit/flag
Name
Set/reset
specification
Forced set/reset data
Memory area code
Bit/flag
Section 6-5