C500LK009V1 Omron, C500LK009V1 Datasheet - Page 9

no-image

C500LK009V1

Manufacturer Part Number
C500LK009V1
Description
PC LINK UNIT
Manufacturer
Omron
Datasheet

Specifications of C500LK009V1

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
About this Manual:
!
This manual describes the installation and operation of C-series SYSMAC LINK Units and includes the
sections described below.
Please read this manual completely and be sure you understand the information provide before attempt-
ing to install and operate a C-series SYSMAC LINK System.
Section 5 Introduction introduces the features and operations possible with SYSMAC LINK Units. It also
describes the possible system configurations and compatibility with PCs and other Link Units.
Section 6 Unit Components and Switch Settings presents the names and functions of the SYSMAC
LINK Units’ components and the switch settings.
Section 7 Installation explains how to install SYSMAC LINK Systems.
Section 8 Basic Communications introduces the token bus method of communications used in SYS-
MAC LINK Systems and explains the basic settings necessary for operation.
Section 9 Data Links describes the operation of data links, procedures required to establish data links,
and methods of monitoring data link operations.
Section 10 Data Read/Write Services describes the data read/write services, which provide data trans-
mission between nodes and distributed control. The data read/write services include the NETWORK
READ (RECV(98)) and NETWORK WRITE (SEND(90)) and instructions and CV-mode commands.
Section 11 Special Services provides information on remote programming and monitoring and RAS
functions.
Section 12 Error Processing provides information to help identify and correct errors that might occur in
the System.
Section 13 Inspection and Maintenance describes periodic maintenance required by the System and
how to replace a SYSMAC LINK Unit.
WARNING
Failure to read and understand the information provided in this manual may result in
personal injury or death, damage to the product, or product failure. Please read each
section in its entirety and be sure you understand the information provided in the section
and related sections before attempting any of the procedures or operations given.
ix

Related parts for C500LK009V1