C500LK009V1 Omron, C500LK009V1 Datasheet - Page 77

no-image

C500LK009V1

Manufacturer Part Number
C500LK009V1
Description
PC LINK UNIT
Manufacturer
Omron
Datasheet

Specifications of C500LK009V1

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Data Link Characteristics
Example
Status Areas
5-10 Data Link Characteristics
5-10-1 Data Link Communications Cycle Time
Note
Note The C200Hj PCs include the C200HX, C200HG, C200HE, and C200HS.
Each of the above sets of four bits contains the four flags indicating data link sta-
tus for a node, as shown below.
This example illustrates the location of data link status flags for a 10-node data
link with the following parameters. These are the only words that will be used.
The following memory areas can be used to store the status data. Be sure to
allow enough words after the beginning status word so that the entire link status
area fits within the same data area.
Data link servicing is given priority in SYSMAC LINK Systems. The communica-
tions time for a data link can thus be maintained as a constant, regardless of
whether or not SEND(90)/RECV(98) are used. Fixing the data link communica-
tions time at a constant value fixes the data link I/O response time as well.
00, 04, 08, or 12
01, 05, 09, or 13
02, 06, 10, or 14
03, 07, 11, or 15
Refreshed nodes
Beginning status word
DM 0120
DM 0121
DM 0122
IR and SR 0 to 252, 300 to 511
LR
HR
AR
T/C
DM
1. *The PC Mode and PC Fatal Error Flags are not valid when a communica-
2. This status must not overlap other areas which may be in use (for example,
Area
tions error has occurred.
the data link area, SEND(90)/RECV(98) area, or areas used by the other
Network).
Word
Bits
0 to 63
0 to 99
0 to 27
0 to 511
0 to 5999
Node 1
Node 10
Node 55
C200Hj
PC Mode*
PC Fatal Error*
Communications
Error
Data Link Status
00 to 03
Flag
1, 2, 3, 4, 10, 15, 20, 28, 55, 62
DM 0120
Node 2
Node 15
Node 62
0 to 252
0 to 63
0 to 99
0 to 27
0 to 511
0 to 999
04 to 07
C200H
Turned ON to indicate the PC is in RUN or
MONITOR mode. OFF indicates
PROGRAM mode.
Turned ON to indicate the PC has stopped
because of a fatal error.
Turned ON to indicate that there is a
communications error (time out), that the
Unit is not part of the System, or that the
data link is not active.
Turned ON to indicate the node is part of
the data link. OFF indicates that the data
link tables of the start-up node do not
match, or no operation is possible because
the data link table has not been created.
Bits
0 to 252
0 to 63
0 to 99
0 to 27
0 to 511
0 to 4095
Node 3
Node 20
(Not used.)
C1000H
08 to 11
Function
Section 5-10
0 to 252
0 to 63
0 to 99
0 to 27
0 to 511
0 to 4095
Node 4
Node 28
(Not used.)
C2000H
12 to 15
63