Up to 2 Link Units can be mounted on a C-series PC at one time. Link Units
include SYSMAC LINK Units, SYSMAC NET Link Units, Host Link Units, and
PC Card Unit (C200HX/HG/HE CPU Units only). For details refer to 1-4-2
Compatibility with other Link Units .
When two Link Units are mounted on one PC, it is necessary to differentiate
between the two Networks to which the PC belongs. Units in one Network
are assigned to operating level 0; Units in the other Network are assigned to
operating level 1. These operating levels only distinguish between the two
Networks and do not imply that one Network is operating above or below the
other in any functional sense.
The operating level of all SYSMAC LINK Units (C1000H-SLK11/SLK21-V1 and
C200HW-SLK13/14/23/24) is set with pin 3 of DIP switch 1, as shown below.
This setting is available on the C1000H-SLK11 and C1000H-SLK21-V1 only.
The PC mode at start-up can be set to MONITOR if it is not being controlled
from the Programming Console of other Peripheral Device that might be con-
nected to the PC.
The PC mode at start-up is set with pin 5 of DIP switch 1, as shown in the table
below.
ON (1)
OFF (0)
ON (1)
3. The token is passed from node to node according to node numbers, so the
4. When a node number has been changed, activate that node last.
1. Always turn the PC’s power off before setting a Unit’s operating level.
2. When mounting a SYSMAC LINK Unit on the same PC with a SYSMAC NET
Pin 5
more dispersed the node numbers are, the greater distance the token has to
travel. In optical fiber systems, the communications cycle time depends on
the distance the token has to travel, so set node numbers according to the
nodes positions in the network if possible.
Link Unit, Host Link Unit (Rack-mounting type), or PC Card Unit, be sure
they are set to different operating levels.
DIP switch 1, pin 3
None
Programming Console
Host Link Unit
(CPU Unit-mounting type)
Host Link Unit
(Backplane-mounting type) DIP switch 1, pin 8: OFF (0)
SYSMAC NET Link Unit
SYSMAC LINK Unit
Other Peripheral Devices
Other unit connected
1
Operating level 0
Operating level 1
4
---
RUN
MONITOR
PROGRAM
DIP switch 1, pin 8: ON (1)
DIP switch 1, pin 8: OFF (0)
DIP switch 1, pin 8: ON (1)
DIP switch 3, pin 1: ON (1)
DIP switch 3, pin 1: OFF (0)
DIP switch 1, pin 5: ON (1)
DIP switch 1, pin 5: OFF (0)
---
Setting on other unit
Operating level
Section 4-4
MONITOR
RUN
MONITOR
PROGRAM
See note 2.
MONITOR
MONITOR
MONITOR
MONITOR
MONITOR
MONITOR
MONITOR
MONITOR
PC mode at
start-up