NT20S-KBA01 Omron, NT20S-KBA01 Datasheet - Page 259

CHEM RESISTANT CVR FOR NT21

NT20S-KBA01

Manufacturer Part Number
NT20S-KBA01
Description
CHEM RESISTANT CVR FOR NT21
Manufacturer
Omron
Datasheets

Specifications of NT20S-KBA01

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
General Specifications
Specifications
Power supply voltage
Allowable power supply voltage range
Power consumption
Inrush current
Ambient operating temperature
Storage temperature
Ambient operating humidity
Operating environment
Resistance to electrostatic discharge
Electromagnetic field strength
Fast transient/burst noise
Damped oscillatory wave
Vibration resistance
Shock resistance
Dimensions (mm)
Weight
Enclosure ratings
Applicable standards
Item
24 VDC
20.4 VDC to 26.4 VDC (24 VDC --15% +10%)
10 W max.
3 A max.
0 to +50_C (with no freezing)
--20 to +70_C
35 to 85% RH (with no condensation)
No corrosive gases.
Level 3 (IEC801-2)
In air 8 kV, contact 6 kV, indirect 7 kV
10 V/m (IEC801-3)
Power supply line: 2 kV (IEC801-4)
I/O line: 0.25 kV
Power supply line: 1 kV (IEC255-4)
10 to 22 Hz with 1.5 mm double amplitude for a total of 30 min. in X, Y, and Z
directions.
22 to 500 Hz with 1.5 G {14.7 m/s
Durability: 30 G, 3 times each in X, Y, and Z directions.
Malfunction: 20 G, 3 times each in X, Y, and Z directions.
190 (W) x 110 (H) x 58 (D) mm
0.7 kg max.
Front panel:
Equivalent to IP65 (front face waterproof construction).
Rear case:
Terminals:
IEC1131-2 (1992)
EN50081-2 (1992)
APPENDIX A
Specifications
IP20
IP00
Specification
2
} acceleration in X, Y, and Z directions.
Appendix A
243

Related parts for NT20S-KBA01