NT20S-KBA01 Omron, NT20S-KBA01 Datasheet - Page 53

CHEM RESISTANT CVR FOR NT21

NT20S-KBA01

Manufacturer Part Number
NT20S-KBA01
Description
CHEM RESISTANT CVR FOR NT21
Manufacturer
Omron
Datasheets

Specifications of NT20S-KBA01

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Connecting to a Host Link Unit
Connection to a PC by the Host Link
External
0V (ON)
Two types of host link units are available: a rack-mounting type and a CPU-
mounted type. The switch settings differ according to the type of host link unit. Set
the switches according to the unit type.
S C200H rack-mounting type: C200H-LK201(-V1)
[Setting the front switches]
Set each switch with a flat blade screwdriver so that the values or symbols in the
setting value window agree with the following.
[Setting the rear switches]
selector
S C500/C1000H/C2000(H) rack-mounting type: C500-LK201-V1
[Setting the front switches]
switch
CTS
5
Local
Host
2
S Mode control (key switch)
Set this to “host link”.
S Unit # (SW1, SW2)
S Instruction level, parity, and transfer code (SW4)
S Baud rate (SW3)
S 1-to-1/1-to-N selection (DIP switch)
S CTS selection (selector switch)
Set these switches to “0”.
Set this switch to “2”.
Set this switch to “5” to select 9600 bps.
Set this switch to “6” to select 19200 bps.
Set #3 to “ON”.
Set this always to “0V” (ON).
Section 2-4
37