NT20S-KBA01 Omron, NT20S-KBA01 Datasheet - Page 44

CHEM RESISTANT CVR FOR NT21

NT20S-KBA01

Manufacturer Part Number
NT20S-KBA01
Description
CHEM RESISTANT CVR FOR NT21
Manufacturer
Omron
Datasheets

Specifications of NT20S-KBA01

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
2-2-2
28
Installation
Installation to the Operation Panel
Caution:
Note:
Note:
The NT20S can be flush mounted to an operation panel.
Use the panel fittings and tools included in the product package and follow the pro-
cedure below.
During work at the panel, take care to ensure that no metal scraps enter the unit.
Otherwise, the product may malfunction.
The thickness of applicable operation panel is 1.6 mm to 4.8 mm. All fittings must
be tightened uniformly to a torque of at least 0.5 to 0.6 N·cm in order to ensure
water- and dust-resistance. The panel must not be soiled or warped, and must be
able to support an installation that will remain secure and strong.
(1) Open a hole, shown below, in the panel and install the NT20S from the front
(2) Attach the panel fittings at four positions, shown below, on the rear side of the
In order to ensure adequate water and dustproof performance, tighten the four
panel fittings uniformly and make sure there are no gaps between the fittings and
the NT20S panel.
side of the panel.
NT20S.
Fit the hook of the fitting in the square hole in the body and tighten the screw
with a Phillips head screwdriver while lightly pulling the fitting.
178.5
+0.5 mm
0 mm
100.5
+0.5 mm
0 mm
Section 2-2

Related parts for NT20S-KBA01