CJ1W-NC414 Omron, CJ1W-NC414 Datasheet - Page 180

no-image

CJ1W-NC414

Manufacturer Part Number
CJ1W-NC414
Description
High Speed Pulse Train 4 Axes
Manufacturer
Omron
Datasheet

Specifications of CJ1W-NC414

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
5
5-3 Axis Parameters
5-19
I/O Function Selection
*1. If you use an absolute encoder system, be sure to use this signal as a RUN output. If you use an
*2. In the case of a Virtual Axis, this setting becomes disabled and the signal is treated as a general-
*3. If you select [0] for origin proximity input signal selection, bits 0 to 3 of the origin proximity input internal
*4. If you select [1] for interrupt input function selection, the target axis of latch depends on [Latch Signal
*5. In the case of a Virtual Axis, this setting becomes disabled and the signals are treated as general
Select the functions of various I/O signals.
I/O function selection becomes enabled at power supply ON, restart, or setup.
RUN Output
Function
Drive Alarm Reset
Output Function
Error Counter Reset
Output Function
Origin Proximity
Input Signal
Selection
Origin Input Signal
Selection
Interrupt Input
Function
Positioning
Completed Input
Function
Drive Alarm Input
Selection
Parameter name
absolute encoder system, read the present position when the RUN output turns ON, upon which the
origin is confirmed.
purpose output.
bit correspond to the origin proximity inputs of axes 1 to 4, respectively. Also, you can use the external
origin proximity input signals as general purpose inputs.
In the case of a Virtual Axis, this setting becomes disabled. You can use the external origin proximity
input signals as general purpose inputs.
Setting] under [Common Parameter].
purpose inputs.
*1 ,*2
*4
*5
*3
*5
*2
*2
Select the function of the RUN output.
0: Use as general-purpose output
1: Use as RUN output
Select the function of the drive alarm
reset output.
0: Use as general-purpose output
1: Use as drive alarm reset output
Select the function of the error counter
reset output.
0: Use as general-purpose output
1: Use as error counter reset output
Select the input destination of the origin
proximity input.
0: Use Origin Proximity Input Internal
1: Use external origin proximity input
Select the input destination of the origin
input.
0: Use Z-phase input as the origin
1: Use external origin input
Select the function of the interrupt input.
0: Use as interrupt feeding trigger
1: Use as present position latch signal
Select the function of the positioning
completed input.
0: Use as general-purpose input
1: Use as positioning completed input
Select the function of the drive alarm
input.
0: Use as general-purpose input
1: Detect drive alarm input as an error
Memory area as the origin proximity
input
CJ Position Control Units OPERATION MANUAL (CJ1W-NC214/234/414/434)
Function
Setting range
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
Unit
Default
values
1
1
1
1
0
0
1
1

Related parts for CJ1W-NC414