CJ1W-NC414 Omron, CJ1W-NC414 Datasheet - Page 297

no-image

CJ1W-NC414

Manufacturer Part Number
CJ1W-NC414
Description
High Speed Pulse Train 4 Axes
Manufacturer
Omron
Datasheet

Specifications of CJ1W-NC414

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
CJ Position Control Units OPERATION MANUAL (CJ1W-NC214/234/414/434)
Similarly, set as follows according to the mechanical configuration.
Maximum Speed
Starting Speed
Acceleration/
Deceleration Time
Selection
Parameter name
Search Speed], [JOG/ Inching Speed] and other speed-related parameters may exceed the
maximum speed. For those parameters that exceed the maximum speed, reset the values to the
maximum speed or lower.
Because you have changed the maximum speed to [500.00mm/s], the default values of [Origin
Reference
Specify the maximum speed of the axis.
Specify the starting speed of the axis.
Select how to specify the acceleration/
deceleration time.
0: Time from starting speed to maximum
1: Time from present speed to target
speed of each axis (acceleration/
deceleration specified)
speed of each axis (time specified)
Function
Set value
50000
0
0
6-7 Sample Program
Command unit/s
Command unit/s
[0.01 mm/s]
[0.01 mm/s]
Unit
6-32
6

Related parts for CJ1W-NC414